30
o
r
Using the Standard Navigation Mode, select whether the search parameters are Fixed, thus
exactly matching the values you will enter into the remaining lines of this menu, or AUTOMATIC:
if so, the meter will explore the frequency range in automatic mode.
Using the Standard Navigation Mode, select RX LEVEL and set the desired CMTS receiving level.
Press ENTER to confirm.
Using the Standard Navigation Mode, select REG. MODE and switch to ON or OFF. Press ENTER to
confirm.
Navigate to the TEST ADDRESS and select if the pinged address will be the active GATEWAY or a
different user defined address (USR DEF.).
In case of User Defined CMTS Address, using standard navigation, select the appropriate IP
address, the OMNIA-7000 will ping. Press ENTER to confirm. You can also dial in the IP address
using the meter numerical keyboard.
To get connected to the CMTS, set up the MAC Address your meter will use to register into the
CMTS. Using the standard navigation mode, highlight the MAC ADDRESS entry and set DEFAULT
to register your meter with the MAC address shows on the last display row, or “USR DEF.” to
manually enter a specific MAC address. To do so, set Usr Def., press ENTER, move the cursor to
the last display row and press ENTER again. Using the standard navigation enter the required
MAC address in hexadecimal form (each couple of digit can be set from “00” to “ff”). Press ENTER
when done.