Barcode Fusions
**The Barcode Fusion Method is always preferred and should be used whenever possible.
When beginning a Barcode Fusion, start from the CONNECT FITTING screen.
Secure the correct fitting adapters
to the
Output Lead Ends
.
Connect both
Output Lead Ends
to the fitting.
When the
Output Lead Ends
are connected to the fitting, the processor will measure the fitting resistance and
display a screen similar to the following:
VERIFYING
RESISTANCE
10.198
After measuring the fitting resistance, the processor will display the following screen:
SCAN BARCODE
Remove the SMART Scanner™ from the protective sheath. Scan the barcode from the fitting about to be
fused. See page 32 for scanning techniques and suggestions.
Whenever possible, use the barcode label attached to the fitting about to be fused. If this is not possible, use
a barcode from an
identical
fitting made by the same manufacturer to ensure that the fusion parameters are
correct.
UNDER NO CIRCUMSTANCES SHOULD A BARCODE FROM A SIMILAR FITTING BE USED.
NOTE:
If the scanning device is inoperative, see page 20 for details about how a fusion can be completed without
using a scanning device.
Once the barcode has been successfully scanned, the
Roughneck Electrofusion Processor
will display a screen
similar to the following:
NOTE:
If Pipe/Fitting Traceability is set to ON or OPT, the operator will be prompted to scan traceability data at this
time. Refer to the appropriate section on page 33 for instructions that detail how to gather this data.
VERIFY SETUP
CPL 2” COUPL
40.0V 60 sec
PRESS START