JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 20 of 48
The VERIFY SETUP screen shows the following information:
•
The fitting type (CPL 2” Coupler).
•
The requested output (40.0 Volts)
•
The total temperature-compensated fusion time in seconds (In this case, 60 seconds).
The VERIFY SETUP screen allows the operator a final opportunity to verify that the fusion parameters
displayed are correct and match the parameters specified by the fitting manufacturer before starting the
fusion.
ALWAYS pay close attention and verify the information on this screen is correct before pressing
START.
The processor will BEEP once per second and the text “PRESS START” on the bottom line of the display will
flash on and off.
Once you have verified that all measurements and parameters are correct, press the
START button
to begin
the fusion.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
NOTE:
If Calculated Resistance is enabled and the operator receives a Warning Code 55, refer to the appropriate
section on page 35 for instructions that detail how to proceed.
See page 24 for instructions on monitoring the progress of a fusion.
Alternate Fusion Methods
Manual Barcode Entry
**The Barcode Fusion Method is always preferred and should be used whenever possible
.
Manual Barcode
Entry Fusions require additional care and attentiveness on the part of the operator to ensure that the
appropriate fusion parameters are entered. For this reason, Manual Barcode Fusions should ONLY be
performed by a fully trained operator us
ing specifications provided by the fitting’s manufacturer.
The Alternate Fusion selection screen can be accessed by pressing the
UP button
and the
DOWN button
at the
same time when the processor is displaying the SCAN BARCODE screen.
The Alternate Fusion selection screen looks like the following:
SELECT METHOD
1 Manual Barcode
2 Manual
Select the desired method by using the
UP button
and the
DOWN button
. When the desired method is
highlighted, press the
START button
.
While in Manual Barcode Mode, the operator can manually input the numbers from the barcode label
attached to the fitting to be fused. The following screen will be displayed: