pressure of the control valve you are using or of the lowest rated component in your system. 

1. PRESSURE RELIEF PROCEDURE 

WARNING: Skin injection hazard:

 The equipment stays pressurized until pressure is manually relieved. 

To  reduce  the  risk of serious  injury  from  pressurized  fluid,  fluid from  the  valve  or  splashing fluid, follow  this 

procedure whenever you: 

  Are instructed to relieve pressure 

  Check, clean or service any system equipment 

  Install or clean dispensing devices 

(1) Pressure relief procedure: 

①.

 Turn off the power supply to the pump. 

②.

 Hold a metal part of the control valve firmly to a grounded metal waste container and point the valve 

outlet toward the waste container, then trigger the control valve to relieve the fluid pressure. 

③.

 Open any bleed-type master air valves and fluid drain valves in the system. 

④.

 Leave the drain valve open until you are ready to pressurize the system. 

(2) Clean the obstruction in the oil system, when any of the following cases occurs:

 

①.

 Problem on control valve, flexible hose, rigid tube or manual/auto tip.   

②.

 Pressure cannot be relieved completely after above procedures are done.   

③.

 It takes more than 5 seconds to relieve the pressure thoroughly.   

 
2. LCD DISPLAY 

INDICATIONS: 

See the following display illustrating the LCD panel.

 

 

Fig. 3 LCD panel displays region 

 

①.

 Partial register measurement exceeds the maximum value will become zero and re-measure. 

②.

 Indication of unit of measurement (L, GAL, PT, QT). 

③.

 Accumulated total. 

④.

 Battery condition (low-power alarm device is built in). 

 

3. OPERATIONAL FUNCTIONS 

The control valve features two keys (MENU and RESET). 

 
(1)  Setting measurement unit 
Solution 1 

①.

 

Press “MENU” and “RESET” simultaneously and hold for about 5 seconds to enter the unit set mode. 

②.

 Press "RESET" to select the unit. 

Summary of Contents for 28481

Page 1: ...TROL VALVE OWNER S MANUAL WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Item 28481 ...

Page 2: ... range 7 1500 PSI Max operation temperature 140 Precision 0 5 Power source one 3 6V ER14250 battery GENERAL SAFETY REGULATIONS WARNING Read and understand all instructions WARNING The warnings cautions and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur It must be understood by the operator that common sense and caution are fact...

Page 3: ...rking pressure of the lowest rated system component This equipment has a 1500 PSI maximum working pressure Make sure all applications comply with local state and national fire electrical and safety regulations Use fluids and solvents that are compatible with the equipment Refer to the Technical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Do not move or ...

Page 4: ...lose the fluid shut off valve 4 as shown in Fig 1 2 Ground the hose and reel or console WARNING To reduce the risk of static sparking effectively ground all equipment Control valve Use proper grounding wire to connect it to the pump Always keep the metal part of the control valve connected with the grounding equipment Pump Follow the manufacturer s instructions for grounding Air and fluid hoses Ma...

Page 5: ...adjust the angle of the nozzle Loosen the 4 swivel nut turn the nozzle to the desired position and tighten the nut NOTE Use oil resistant pipe sealant or Teflon Tape on all fitting threads 1 Installing a new oil control valve When installing a new control valve first apply appropriate thread sealant around the male thread of the oil supplying system then connect the male thread into the female thr...

Page 6: ... master air valves and fluid drain valves in the system Leave the drain valve open until you are ready to pressurize the system 2 Clean the obstruction in the oil system when any of the following cases occurs Problem on control valve flexible hose rigid tube or manual auto tip Pressure cannot be relieved completely after above procedures are done It takes more than 5 seconds to relieve the pressur...

Page 7: ... Press the MENU key Keep it pressed until the digit flashes in Zone Then press the RESET key to choose the right digit from 0 to 9 Press the MENU key to go the next digit so that the Actual Value can be input Make sure the Actual Value is input correctly and then press the MENU key Keep it pressed until calibration is finished and the factor is saved The meter will then return to standby 5 OPERATI...

Page 8: ...ace if damaged If the problem remains contact your distributor for repair or replacement Valve leaks O rings or valve seat are worn or damaged Replace the o rings and or the valve seat If the problem remains contact your distributor for repair or replacement Leakage from meter O ring damaged 1 1 Take the meter off the dispense system 2 2 Take off the rubber protector part 3 4 and front label part ...

Page 9: ... valves to direct sunlight and avoid rain falling corrosive substance etc Storage Store the control valve in a dry place with good ventilation Do not expose it to excessive heat humidity or sunlight Never let it touch any corrosive substances Store it out of the reach of children DIAGRAMS AND PARTS LIST ...

Page 10: ... 1 O ring 1 3 19 Waterproof Protector 2 3 2 Meter Holder 1 3 20 Seal Washer 4 3 3 Meter Cover 1 3 21 Washer 4 3 4 Rubber Protector 1 4 Nozzle with Tip 1 Item No 4 Description Part No Description MH10001 Rigid Nozzle MH10002 Flexible Nozzle MH10001 Manual Tip MT10002 Auto Tip MT10003 Semi auto Tip Wear Parts Part No Description Qty 1 5 O ring 2 1 9 Seat 1 1 13 Filter 1 1 4 Trigger 1 3 1 O ring 1 3 ...

Reviews: