6
③
SYN.CLK control connector
The control for synchronizing two or more transmitters. This function will not be used when a
single apparatus operates. Please consult ‘How to connect for the synchronous control’ for
specific details.
④
FREQUENCY setting switch
Set up a transmission frequency (3-digits), by a step of 0.1MHz and within the range of 76.0
〜
90.0MHz
⑤
RF LEVEL adjustment
Adjust the transmitter’s output level. It increases up to 30dB as you turn the adjustor clockwise.
⑥
RF OUT connector
The output connector (BNC receptacle) of the transmitter. External equipment such as an
antenna, a booster and a
leaky coaxial cable can be connected. Use a coaxial cable (50
Ω
or
75
Ω
) for connection.