© Rototilt Group AB
2017-01-18
Schematics
Valveblock, Tilt R4
1. Tilt
Valveblock, Swivel R4
1. Option/Extra2
2. Grapple/Extra 1
3. Coupler
Control Unit TLEE
1. Red light - Rototilt® in “standby”
mode
2. Yellow light #1 - Input signal from
switch for the selected function
3. Green Light - Output signal from the
selected function.
4. Yellow light #2 - Output signal to
close tilt valve ().
Activated
automatically when using extra
function or quick coupler.
3
2
1
4
3
2
1
1
Schematics and Overwievs for hydraulic as well as electrical systems, in the following pages are meant to
serve mainly as a guide for Troubleshooting.
!
WARNING!
More extensive adjustments and repairs must be done by an authorized service workshop.
English
EN
SCHEMATICS - TLEE Closed