background image

© Rototilt Group AB

2017-01-18

Schematics

Valveblock, Tilt R4

1. Tilt

Valveblock, Swivel R4

1. Option/Extra2
2. Grapple/Extra 1
3. Coupler

Control Unit TLEE

1. Red light - Rototilt® in “standby”

mode

2. Yellow light #1 - Input signal from

switch for the selected function

3. Green Light - Output signal from the

selected function.

4. Yellow light #2 - Output signal to

close tilt valve (). 

Activated

automatically when using extra

function or quick coupler.

3

2

1

4

3

2

1

1

Schematics and Overwievs for hydraulic as well as electrical systems, in the following pages are meant to 

serve mainly as a guide for Troubleshooting.

!

WARNING! 

More extensive adjustments and repairs must be done by an authorized service workshop.

English

EN

SCHEMATICS - TLEE Closed

Summary of Contents for TLE

Page 1: ...2200256_6361 2017 01 18 ML Control System TLEE Closed R4 Instructions for use translated from the original Swedish ...

Page 2: ...rom switch for the selected function yellow LED on 3 Output signal from the selected function green LED on 4 Output signal to open tilt valve remote Activated automatically when using the extra function or quick coupler yellow LED on ON OFF switch for Rototilt The electrical control system is turned on and off with the switch The switch must be ON to operate the various Rototilt functions The bloc...

Page 3: ...n is separately connected directly to the base machine s hydraulic system and can be used independently of other Rototilt functions The tilt extra extra 2 functions and the quick coupler locking function are mutually dependent on each other and can therefore not be used simultaneously Functions are selected via the directional valves on Rototilt Extra When the switch is activated the directional v...

Page 4: ...decal Always pressurize Rototilt in order to activate the locking cylinder in the quick coupler Switch and buzzer for the quick coupler locking function The switch 1 activates the quick coupler locking function control valve on Rototilt to the open or closed position The blocking function locks the switch in the open position and the blocking function should prevent unintentional activation of the...

Page 5: ...unction manually via the foot pedal When Rototilt is pressurized the quick coupler locking function opens hydraulically and the indicator on the quick coupler shows that the lock is open See section for quick coupler 3 Once the locking wedge on the quick coupler is fully open release the worktool by carefully retracting the bucket cylinder Figure 1 Figure 2 Figure 3 Disconnect Rototilt from the ba...

Page 6: ... via the foot pedal See warning decal changing worktool 4 Check that the worktool is securely locked in the quick coupler see IMPORTANT below IMPORTANT Checking the quick coupler locking function Even if the indicator shows that the locking wedge is in the locked position always conduct the following test to ensure it is correctly secured Push the worktool forwards against the ground see Figure 4 ...

Page 7: ...Light Output signal from the selected function 4 Yellow light 2 Output signal to close tilt valve remote Activated automatically when using extra function or quick coupler 3 2 1 4 3 2 1 1 Schematics and Overwievs for hydraulic as well as electrical systems in the following pages are meant to serve mainly as a guide for Troubleshooting WARNING More extensive adjustments and repairs must be done by ...

Page 8: ... Rototilt Group AB 2017 01 18 Hydraulic Schematic TLEE Closed R4 English EN SCHEMATICS TLEE Closed ...

Page 9: ... Rototilt Group AB 2017 01 18 Schematic El System TLEE Closed Machine English EN SCHEMATICS TLEE Closed ...

Page 10: ... Rototilt Group AB 2017 01 18 LOCKING CYLINDER SEPARATE GROUND LOCKING CYLINDER COMMON GROUND TILT EXTRA EXTRA2 Schematic El System TLEE Closed R4 English EN SCHEMATICS TLEE Closed ...

Reviews: