background image

19

 2200179_     _ 7225     2018-04-23

© Rototilt Group AB

Instructions_Grapple

Max

25 MPa

1

2

2

1

3

4

EN

!

WARNING! 

The grapple is fitted with an accumulator.

 

It is a high-pressure pressure vessel that must 

be discharged before any kind of service work. 

Undo the connections carefully.

Grapple cylinder

The grapple cylinder has inbuilt buffering 

at its inner end position. 
Following connection to the hydraulic 

system, the cylinder must be vented 

by slowly running it to its end positions 

a few times.

1.

Connection, Open (-)

2.

Connection, Close (+)

3.

Accumulator, pressurized ≤20 MPa

4. Load-holding valve
The grapple cylinder is operated by a 

double-acting hydraulic circuit. Oil flow 

on the cylinder (+) side closes the grapple 

arms, while oil flow on the cylinder (-) 

side opens the grapple arms.
The grapple’s hydraulic system includes 

a safety device that makes sure grapple 

functions are not lost in the case of an 

unintentional pressure drop in the base 

machine hydraulic system.
The safety device comprises a load 

holding valve and accumulator. The 

load holding valve maintains hydraulic 

pressure on the grapple (+) side, which 

prevents unintentional grapple opening. 

The pressurized gas in the accumulator 

is compressed further by hydraulic 

pressure at the start of work. This 

automatically adjusts the grapple if the 

load shifts.

Warning decals

1.

Maximum working pressure 25MPa;

affixed to the grapple chassis.

2.

Pressurized equipment; affixed to

the accumulator.

!

IMPORTANT! 

the decals are extremely important for safety 

when operating the grapple.  

Keep the warning decals fully legible.