background image

MINI 5 

p. 3 

MARCH 2011 

7.

 

WATER FILLING 

 

When the water in the boiler is over, the lamp “no water” switches on (fig. 2 E). So MINI 5 has 
to be switched off by disconnecting the plug; rotate the valve plug (fig. 3) of 360° and wait for 
steam to go out completely. Unscrew the valve plug with care and wait a few minutes. Then fill 
the  boiler  with  water.  Screw  the  valve  plug  again,  connect  the  plug  and  wait  for  the  boiler 
lamp to switch off (fig. 2 D). Now the iron is ready again.  

 

 

 

Fig. 5  

 

 

 

 

 

 

Fig. 6 

 

 

8.

 

EMPTYING OF BOILER 

Procedure to be carried out with MINI 5 switched off and cold (manometer should be at 0  
Bar) and disconnected plug 
Unscrew the valve plug (fig. 4) and tilt the MINI 5 towards the right so that all water and  
impurities come out.  

 
 

9.

 

GOOD FUNCTIONING

 

 

MINI 5 was projected for the ironing of domestic garments. It can be used maximum 20 hrs. 
per week or 80 hrs. per month (subdivided in many times). 

 
 

10.

 

INTERVENTIONS AND SMALL REPAIRS 

 

1. Replace the gasket of the security valve plug (use only original gaskets) every 1200 hrs. of 
ironing or maximum 2 years.  
2. Replace the security valve plug every 2500 hrs. of ironing or maximum 3 years (fig. 3). 
For  carrying  out  these  procedures,  the  machine  has  to  be  switched  off  and  cold  and  the 
manometer has to indicate 0 BAR. 

 
 

11.

 

COMPULSORY PERIODICAL MAINTENANCE 

(To be carried out exclusively by Assistance Centres or by the manufacturer) 

 

It is recommended to replace: 
1.

 

the internal security valve every 2100 hrs. of ironing or maximum 3 years; 

2.

 

the internal thermostats every 2100 hrs. of ironing or maximum 3 years; 

3.

 

steam tube and iron cable once they seem spoilt (fig. 5). 

It  is  recommended  also  to  clean  the  boiler  from  limestone  every  2500  hrs.  of  ironing  or 
maximum 3 years.

 

 
 

12.

 

ELECTRICAL RISKS

 

 

The following situations are considered dangerous for the operator: 

1.

 

earth protector switch is activated when turning on the main switch, 

2.

 

using MINI 5 during thunderstorms, 

3.

 

using MINI 5 without proper protection for feet (without shoes) or with wet feet, 

 

ELECTRIC
WIRE

STEAM
TUBE

THERMOSTAT

 

 

Reviews: