MINI 5
p. 3
MARCH 2011
7.
WATER FILLING
When the water in the boiler is over, the lamp “no water” switches on (fig. 2 E). So MINI 5 has
to be switched off by disconnecting the plug; rotate the valve plug (fig. 3) of 360° and wait for
steam to go out completely. Unscrew the valve plug with care and wait a few minutes. Then fill
the boiler with water. Screw the valve plug again, connect the plug and wait for the boiler
lamp to switch off (fig. 2 D). Now the iron is ready again.
Fig. 5
Fig. 6
8.
EMPTYING OF BOILER
Procedure to be carried out with MINI 5 switched off and cold (manometer should be at 0
Bar) and disconnected plug
Unscrew the valve plug (fig. 4) and tilt the MINI 5 towards the right so that all water and
impurities come out.
9.
GOOD FUNCTIONING
MINI 5 was projected for the ironing of domestic garments. It can be used maximum 20 hrs.
per week or 80 hrs. per month (subdivided in many times).
10.
INTERVENTIONS AND SMALL REPAIRS
1. Replace the gasket of the security valve plug (use only original gaskets) every 1200 hrs. of
ironing or maximum 2 years.
2. Replace the security valve plug every 2500 hrs. of ironing or maximum 3 years (fig. 3).
For carrying out these procedures, the machine has to be switched off and cold and the
manometer has to indicate 0 BAR.
11.
COMPULSORY PERIODICAL MAINTENANCE
(To be carried out exclusively by Assistance Centres or by the manufacturer)
It is recommended to replace:
1.
the internal security valve every 2100 hrs. of ironing or maximum 3 years;
2.
the internal thermostats every 2100 hrs. of ironing or maximum 3 years;
3.
steam tube and iron cable once they seem spoilt (fig. 5).
It is recommended also to clean the boiler from limestone every 2500 hrs. of ironing or
maximum 3 years.
12.
ELECTRICAL RISKS
The following situations are considered dangerous for the operator:
1.
earth protector switch is activated when turning on the main switch,
2.
using MINI 5 during thunderstorms,
3.
using MINI 5 without proper protection for feet (without shoes) or with wet feet,
ELECTRIC
WIRE
STEAM
TUBE
THERMOSTAT