8 Dismantling
WARNING
Improper dismantling may pose a risk of death!
The sash may fall during dismantling.
u
Secure the sash to prevent it from falling, e.g. by using two people.
u
Always have dismantling work performed by a specialist company.
CAUTION
Physical strain may cause injury and damage to health.
Carrying and lifting heavy loads for extended periods leads to physical injury in the long term.
u
When carrying or lifting loads, maintain an ergonomically correct posture. The maximum permissible
load is 25 kg for men and 10 kg for women.
INFO
Unless otherwise stated, dismantling is performed in reverse order to installation.
8.1 Dismantling
1. Stop the power supply. Pull out the connector.
2. Undo and remove the screw.
3. Undo the plug connection with a hex key or suitable screwdriver.
ATTENTION
A faulty spring may cause property damage.
Undoing the plug connection in an uncontrolled manner may damage the spring.
u
Do not pull on the spring to undo the plug connection.
u
Use a hex key or suitable screwdriver to undo the plug connection.
4. Unhinge the sash.
5. Protect the plug connection against dust and moisture.
Dismantling
40 ·
05 / 2020
·
IMO_502_EN_v2
Roto Safe - Cable junctions
Subject to change.