Page 12
4. Avoid sudden uphill turns on steep slopes.
5. Do not drink and drive.
6. Comply with state and local laws governing highway safety.
7. Plan your route to avoid heavy traffic.
8. Be a safe courteous driver. Always yield to oncoming traffic in all situations, including narrow bridges,
intersections, etc.
9. Be observant of bridge loading ratings. Do not cross bridges rated lower than the gross weight at which
you are operating.
10. Watch for obstructions overhead and to the side while transporting.
11. Make allowances for increased length and weight of the spreader when making turns, stopping the unit,
etc.
OPERATION
LOADING
Park the spreader for loading. Put the truck in PARK or NEUTRAL and apply the parking brake.
Make sure the sliding front gate is all the way to the front of the spreader and close the hydraulic rear gate
before loading.
It is unlawful to allow any manure spillage to occur on public roadways. Be sure rear gate is fully closed and
sliding gate scrapers are adjusted so no liquid leakage occurs. Do not heap load such that manure is allowed
to fall off spreader during transporting on roadways.
Load the spreader. The moisture content will determine how full it can be loaded. See SPECIFICATIONS for
capacity. Solid manure can generally be loaded level to slightly heaped. High moisture slurries are heavier
and loading may be limited.
UNLOADING
1. Press beater switch to “ON” (WHENEVER THE BEATER IS USED ALWAYS PLACE SWITCH IN THE
ON POSITION BEFORE ENGAGING THE PTO).
2. Press “ON” button.
3. Engage PTO.
4. Press rear gate switch “UP” to raise gate completely.
5. When gate is completely raised return rear gate switch to center.
6. Press belt switch “BACK” to start floor.
7. Adjust belt speed “DIAL” for desired floor speed.
8. Select correct gear to maintain engine RPM to 1500-2100 and give the desired rate of application to the
field. (A combination of gear selections and “DIAL” settings will fine tune the rate of application).
9. Start forward motion of truck when “SPREAD” light comes on.
10. When “SPREAD” light goes out the load is emptied.