1.
Description
Dear customer,
Congratulations on the purchase of a
ROFROST
TURBO II
pipe freezing system.
The ROTHENBERGER HIGH TECH pipe freezing
system with a hermetically sealed refrigerant cycle
is used for freezing copper pipes with a diameter
of 10 - 60 mm or 3/8“ - 2.1/8“ and steel pipes with
a d i a m e t e r o f 1 / 8 “ - 2 “ r a p i d l y, s a f e l y a n d i n a n
environmentally-friendly manner.
Freezing of multiple pipes is possible after con-
s u l t a t i o n w i t h R O T H E N B E R G E R W E R K Z E U G E
AG.
For the sanitary and central heating system instal-
l e r, t h e
R O F R O S T T U R B O I I
p ro v i d e s a n e c o -
nomically-efficient solution to his problems, since
maintenance, repair and extension work on exi-
s t i n g p i p e s y s t e m s c a n b e c a r r i e d o u t w i t h o u t
time-consuming draining down of the pipes or the
additional installation of shut-off devices.
This means that your customers and their neigh-
b o u r s ( e . g . i n a n a p a r t m e n t h o u s e ) d o n o t h a v e
problems making appointments and are not incon-
venienced, particularly during the colder times of
year, since the adverse effects caused by lengt-
h y d i s c o n n e c t i o n o f t h e c e n t r a l h e a t i n g o r t h e
water supply no longer occur.
The
ROFROST TURBO II
is perfect for replacing
defective components such as radiators, valves,
thermostatic valves etc., while substantially redu-
cing the harmful influence of oxygen in the heat-
ing system.
1.1 Contents
T h e
R O F R O S T T U R B O I I
p i p e f re e z i n g s y s t e m
basically consists of the following components:
1. E l e c t r i c re f r i g e r a t i n g s e t w i t h c a s e , c a r r y i n g
handle cover, plastic inset and mains cable
2. 2 refrigerant hoses
3. 2 f re e z e c l a m p s f o r c o p p e r p i p e s w i t h a d i a -
meter of 60 mm or 2.1/8“ and for steel pipes
with a diameter of 2“
4. 2 thermistors
5. On/off switch
6. Set of reduction inserts (sizes A/D/E/F)
7. 1 tin of heat transfer compound
Special sizes for reduction inserts on inquiry.
Thermally insulated protective gloves to DIN EN
511.
2.
Technical data
GB
USA
Euro
062204 062205
062203
Rated voltage
110 V
115 V 230-230 V
Rated frequency:
50 Hz
60 Hz
50 Hz
Rated power:
310 W 310 W
325 W
Refrigerant:
R404a
Filling weight:
160 g
Weight of appliance: approx. 25 kg
Dimensions (L/W/H): 500 x 253 x 315 mm
Noise level
ⱕ
70 dB (A)
Permissible temperature during operation:
-15°C to + 40°C
3.
Safety requirements
Careful and cautious handling and the observance
o f t h e o p e r a t i n g i n s t r u c t i o n s a n d s a f e t y i n f o r -
mation for electric tools are prerequisite for the
p re v e n t i o n o f a c c i d e n t s w h e n u s i n g m a c h i n e r y
and tools. Please ensure that only authorised per-
sonnel operate the appliance!
Personnel being trained in the use of the appli-
ance or those undergoing a general training are
only allowed to work with it while under the con-
stant supervision of an experienced person!
T h e a p p l i a n c e m a y o n l y b e o p e r a t e d w h e n i t i s
in a safe and functioning condition! Cluttered-up
w o r k p l a c e s a r e o f t e n t h e c a u s e o f a c c i d e n t s .
Always ensure that workplaces are kept tidy!
Do not work in dangerous circumstances!
Unused tools should be kept dry and out of reach
of children under lock and key!
Never pull the plug out of the socket by the cable.
Keep cable away from oil, heat sources and sharp
edges. Replace the mains cable and cable grips
immediately, if they are damaged or wor n.
Always remove the plug from the socket when the
a p p l i a n c e i s n o t i n u s e o r d u r i n g t o o l c h a n g e s ,
maintenance or repair!
Always ensure that there is adequate lighting at
the workplace!
The appliance may be only used in dry premises!
-5-