ENGLISH
13
Remove the equipment from the wall immediately in the event of a power
failure
. Danger due to the equipment falling off. Vacuum neutralised. Only work using
slight feed pressure.
Please read and be sure to understand the supplied vacuum pump instruction
manual
3.4 Handling
Changing the side of the hand wheel:
Make sure the feed gear cannot be operated unintentionally. Use the locking button
(1) to secure the feed unit.
Î
Withdraw the black cap nut and remove the hand adapter
(11)
.
Î
Insert on the desired side and re-secure using the cap nut.
Setting the drill angle:
Î
Loosen the toggle
(7)
and set the guide column
(3)
at the desired angle (15°- 30°- 45°).
Î
Re-tighten the toggle
(7)
.
Applying the diamond drill:
Make sure the feed gear cannot be operated unintentionally. Use the locking button
(1) to secure the feed unit.
Î
RODIACUT 131 DWS: Insert the motor into the receptacle
(2)
of the drill rig from the top and
fasten by means of the screw.
Î
RODIACUT 202 DWS: Slide the motor from the top as far as it will go (stop
15
) into the feed
unit
(10)
of the drill rig and tighten using both star handles
(14)
.
Î
Proceed in the reverse order in order to remove.
Setting the depth control stop:
Î
Release the screw at the depth control stop
(4)
and set the desired drill depth.
Î
Re-tighten the screw firmly.
Water extraction device (accessory picture B-4):
Î
RODIACUT 131 DWS: Unscrew both front ring bolts
(5)
. Turn the knurled screws on the
water extraction device into the ring bolts and re-insert in the base plate.
Î
RODIACUT 202 DWS: Turn both screws with knurled screws on the water extraction device
into the boreholes
(19)
in the base plate intended for this purpose.
Î
Fasten the water extraction device over the ring bolts
(5)
by means of the spring lock or lock
the screws in place and fasten by means of the knurled screws.
Î
Connect the water extractor and attach the suction hose to the connecting piece of the water
extraction ring.
Î
Create a water intake.
-hose feed directly at water supply or
-immersion pump with bucket
PLEASE NOTE:
Adequate water supply for cooling the drill bit must always be ensured,
as otherwise the drill bits can overheat very quickly and segments can come away.
Information:
We strongly advise against the use of “water pressure reservoirs“ as from a drill
diameter of 200 mm, as adequate control of the water supply is very restricted in this case.
Î
Cut a hole in the rubber sheet appropriate to the drill bit diameter (air gap between the cut-
out rubber seal and drill bit approx. 2-3 mm).
Î
Place the rubber sheet on the water extraction ring.