ENGLISH
17
When joining welding necks always use the flange adapter (optional accessory, must be ordered
separately).
To insert and remove the trimmer and the heating plate we recommend using the electrical hoist
(optional accessory, must be ordered separately).
3.1.1 Overview
(A)
1
Hydraulic unit
3.8
Pressure release switch
2
Basic machine
3.9
Basic machine close
3
Power control box
3.10
Adjustment pressure button
3.1
Trimmer unit plug in
4
Storage case
3.2
Heating element plug in
5
Remote control cable (optional)
3.3
Remote control cable plug in
5.1
Adjustment pressure button
3.4
Main switch
5.2
Pressure release switch
3.5
Heating element switch
5.3
Joystick
3.6
Controller
6
Trimmer unit switch off
3.7
Basic machine open
7
Trimmer unit switch on
3.2
Operating instructions
In accordance with national or EU ordinances and guidelines, e. g. DVS 2212, Section I,
only duly qualified and authorised personnel are allowed to operate the ROWELD weld-
ing machines!
Only trained and authorised welders are allowed to operate the machine!
3.2.1 Putting into operation
Please read through the operating instructions and safety instructions attentively before
you put the butt fusion welding machine into operation!
Do not use the heating element in explosive environments or bring it into contact with
easily flammable materials!
Stay a safe distance away from the machine. Do not stand or reach into the machine.
Keep other people away from the work area!
Before every start-up, check the oil level of the hydraulic unit. The oil level must be
between the min. and max. marking on dipstick in the oil filler cap. If necessary, add
HLP 46 hydraulic oil!
Transport and set the hydraulic unit only in a horizontal position. If it is set at an angle,
oil escapes from the vented plugs with the dipstick!
Connect the hydraulic unit to the basic unit with hydraulic hoses.
Protect the quick couplings from contamination. Replace leaky couplings immediately!
Connect the mains plugs of control box modul to the power outlet/supply specified on the
type plates.
Connect the trimmer unit, heating plate and remote control cable mains plugs to the control
box modul.
Switch on the main switch (3.4) of control box modul.
Heating element (3.5) switch on. Button lights on, if heating element switching on
Set temperature controller (3.6) to the correct fusion temperature.
The rise in temperature is indicated by a red signal lamp on the temperature controller.
The display generally indicates the actual temperature value. In accordance with national ordi-
nances and guidelines, e. g. DVS, the heating plate is ready after maintaining the setpoint tem-
perature for at least 10 minutes.
Check the temperature with a temperature measurement device.
Summary of Contents for 54274