ENGLISH
11
2.4
Opening the Unit
The cover of the product may be removed only by specialized staff of the
company ROTHENBERGER or of a partner organization properly trained and
approved by it!
2.5
Checking for Damage
Every time before operating the product, carefully check safety features or possibly existing
parts with minor damage for intended and proper function work properly, that contact is fully es-
tablished, and that the contact surfaces are clean. All parts have to be installed correctly and
properly conform to all conditions in order for the operator to be sure that the product works as
intended. Damaged safety features or functional parts should be properly repaired or replaced
by a qualified organization/ service shop.
2.6
Mains Power Supply
Utility suppliers’ wiring requirements, VDE provisions, occupational safety rules, DIN / CEN
regulations, and national codes have to be respected.
Mains power fuse protection ROFUSE Sani 160 should be min. 10 A.
Mains power fuse protection ROFUSE Sani 315 should be min. 16 A.
The product has to be protected against rain and humidity.
3
Service
3.1
Maintenance and Repair
As the product is used in applications that are sensitive to safety considerations, it may be ser-
viced and repaired only by the manufacturer or its duly authorized and trained partners. Thus,
constantly high standards of operation quality and safety are maintained.
Failure to comply with this provision will dispense the manufacturer from any warranty and liabil-
ity claims for the product, including any consequential damage.
When serviced, the unit is upgraded automatically to the technical specifications of the product
at the moment it is serviced, and we grant a three-month functional warranty on the serviced
unit.
We recommend having the product serviced at least every twelve months.
In Germany, do not neglect that the occupational safety check-up under rule BGV A3 is manda-
tory!
3.2
Transport, Storage, Shipment
The product is shipped in ROCASE. Store the product in the ROCASE dry and protected against
humidity.
When shipped, the product should be placed into the ROCASE at any time.
4
Principle of Operation
The ROWELD ROFUSE Sani 160 & 315 welding unit allows using electrofusion fittings to join
discharge lines routed indoors and made of PE, of the makes Geberit, Akatherm-Euro, Coes,
Valsir, Waviduo, and Vulcathene-Euro.
The microprocessor-controlled unit
• controls and monitors the welding process in a fully automated fashion,
• determines welding duration depending on ambient temperature,
• Displays all of the information on a full graphic display.
5
Operation
5.1
Turning the Welding Unit On
After connecting the power supply cord to 230 V mains power, turn the welding unit on at the
On/Off switch. The electronics will immediately check all of the parameters and contacts for cor-
rectness and those that do not fit in the display (warnings) will be displayed as symbols.
The display will switch over to the welding mode if no errors are detected.