GB
16
STORAGE AND TRANSPORT
- If the burner is not to be used keep it at a safe, cool, dry and well-ventilated place out of
the reach of children.
- Protect the gas cylinder from sunlight and never expose it to temperatures above 50°C.
- The gas tank must be detached if the burner is not to be used over longer periods, or if it
is to be transported.
- Reusable tanks must always be refilled at authorised companies. Improper refilling can
lead to serious accidents.
- In general, all national regulations regarding operation, transportation and storage have
to be respected.
TROUBLESHOOTING
Problem
Possible cause
Troubleshooting
Appliance cannot be
switched on
On/off switch defective
Obtain a replacement
switch from our service
centre and have these fitted
by an authorised person.
No power supply.
Check the plug and the
mains socket
Gas valve closed
Open the cylinder valve
Gas cylinder empty
Replace the gas cylinder
Pressure regulator defective Purchase a replacement
pressure regulator from our
service center and mount it
as described above
Roturbo 35000 SA:
Gas regulating valve not on
max. position
Turn the valve anti-
clockwise to max. position.
Hose failure safety device
blocks the gas flow
Press the pressure release
button of the hose failure
safety device
Flame very weak, unsteady,
yellow...
Gas cylinder almost
empty
Replace the gas cylinder
Pressure regulator defective
Purchase a replacement
pressure regulator from our
service center and mount it
as described above
Flame extinguished as soon
as the gas feed button is
released
Safety cut out has cut off
the gas supply
Repeat the ignition procedure
and keep the gas feed button
pressed for a longer time
Summary of Contents for ROTURBO 12000