7 Technical data

Installation manual

12

RBLQ011~016CAW1

ROTEX HPSU monobloc compact outdoor unit

4P537991-1 – 2018.08

English

Translation

Outdoor

Outdoor

Use normal kWh rate power
supply for hydro switch box

Use normal kWh rate power
supply for hydro switch box

A1P

Main PCB

A2P

Current loop PCB

B1L

Flow sensor

E11H

Flextube heater (15.6 W)

E12H

Expansion vessel heater (50 W)

E13H

PHE heater (50 W)

E14H

Internal pipe heater 1 (50 W)

E15H

Internal pipe heater 2 (33 W)

F1U (A1P)

Fuse T5 A 250V

K*R (A1P)

Magnetic relay

English

Translation

M1P

Main supply pump

Q4DI

#

Earth leakage circuit breaker

R1T

Outlet water heat exchanger
thermistor

R3T

Refrigerant liquid side thermistor

R4T

Inlet water thermistor

R6T

*

External outdoor ambient sensor

S1L

Flow switch

TR1

Power supply transformer

X*A, X*Y (A1P, A2P)

Connector

X*M

Terminal strip

*:

Optional

#:

Field supply

Electrical connection diagram

Hydro switch box

Power Supply

Q4DI

X3M

X5M

X5M

XAG1

X1M

3N~, 50 Hz

400 V AC

Power supply

N

L3

L2

L1

L3

L2

L1

N

M2S

NO Valve

1

2

2

1

2

1

1

2

5

6

external outdoor ambient

sensor option

R6T

-t°

Summary of Contents for RBLQ011CAW1

Page 1: ...Installation manual ROTEX HPSU monobloc compact outdoor unit English Installation manual ROTEX HPSU monobloc compact outdoor unit RBLQ011CAW1 RBLQ014CAW1 RBLQ016CAW1...

Page 2: ...B C 500 250 100 A B C E 500 250 150 1000 500 500 D 500 500 D E 1000 500 B D 250 500 B D E 250 250 400 400 400 400 400 1000 150 150 150 150 150 150 150 1000 1000 1000 500 HD HU HD HU HB HU HD HU HB HU...

Page 3: ...v daj n sleduj c m norm m nebo normativn m dokument m u skladu sa slijede im standardom ima ili drugim normativnim dokumentom ima uz uvjet da se oni koriste u skladu s na im uputama 16 17 18 19 20 21...

Page 4: ...3 To connect the remote outdoor sensor 8 4 4 4 To connect the shut off valve 9 5 Commissioning 9 5 1 Checklist before commissioning 9 6 Hand over to the user 9 7 Technical data 10 7 1 Piping diagram...

Page 5: ...water volume in the installation is minimum 80 litre the internal water volume of the outdoor unit NOT included INFORMATION In critical processes or in rooms with a high heat load extra water might b...

Page 6: ...s follows 150 6 2 0 350 3 4 5 3 5 5 a mm 2 6 1 5 6 M12 a Make sure not to cover the drain holes INFORMATION The recommended height of the upper protruding part of the bolts is 20 mm 20 NOTICE Fix the...

Page 7: ...the outdoor unit 3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cables from scratching the paint field supply 4 Attach the ends of the cables and tighten them 4 3 Conne...

Page 8: ...4 1 To connect the electrical wiring on the outdoor unit 1 Remove the switch box cover See 4 1 1 To open the outdoor unit on page 5 2 Insert the wiring at the back of the unit a b c 25 mm a Low voltag...

Page 9: ...een the outdoor unit and the HPSU monobloc tank The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this d...

Page 10: ...nt liquid side thermistor 12 Inlet water thermistor 13 Gas stop valve with service port 14 Electronic expansion valve main 15 4 way valve 16 Not applicable 17 High pressure switch 18 Compressor 19 Pre...

Page 11: ...kcase heater F1U F2U A1P Fuse T 31 5 A 500 V F3U F6U A1P Fuse T 6 3 A 500 V F7U A2P Fuse T 5 A 250 V F8U F9U Fuse F 1 A 250 V H1P H7P A2P LED service monitor is orange HAP A1P A2P LED service monitor...

Page 12: ...15H Internal pipe heater 2 33 W F1U A1P Fuse T5 A 250V K R A1P Magnetic relay English Translation M1P Main supply pump Q4DI Earth leakage circuit breaker R1T Outlet water heat exchanger thermistor R3T...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...r partners abroad Unsere Partner im Ausland Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http de rotex...

Reviews: