![Rotem P-COMM-V1 User & Installation Manual Download Page 17](http://html1.mh-extra.com/html/rotem/p-comm-v1/p-comm-v1_user-and-installation-manual_1490994017.webp)
17
Communicator
|
3.05
5.1.1.3 Testing the Voice Call Service
This menu tests the
VOICE CALL
service.
1. Select
SYSTEM > Test > Dial Out
.
2. Enter the required phone number to receive the “Test Call”.
3. Press
ENTER
.
5.1.1.4 Testing the Cellular Signal Strength
•
Select
SYSTEM > Test > GSM
.
This screen displays the cellular service provider’s Received Signal Strength Indicator. This screen
displays the cellular service provider’s number, name, BER (Bit Error Rate (if available)), the reception
bar graph as well as the measured signal reading.
NOTE:
Signal strength must be between -113 dBm to -51 dBm.
5.1.1.5 Receiving a Status Report
You can receive a status report over the phone. Refer to Status Report, page 21 for details on the
function.
To hear the status report:
1. Call the Communicator phone number.
2. When prompted, select Status report.
5.1.2 Advanced Voice Functions
This section details Communicator’s advanced Voice functions.
CAUTION Rotem recommends that only trained, authorized technicians configure these
functions.
•
Configuring the Telephone Modem, page 18
•
Defining when Communicator Answers Incoming Calls, page 18
ENTER NUMBER
23415
RED WIRELESS
<Ber=…>
-51 dBm