8

RLC-1040 

Power Conditioner

Setting Up the RLC-1040

Use the front panel 

Setup

 and 

Select

 buttons 

-

 

=

 to configure the various features and 

functions of the RLC-1040 

Dimmer Function

This function sets the brightness level of the front 
panel LCD Display and the LED indicators. Press 
the 

Setup

 button once to access the Dimmer 

Function display. 

������������������
������������������

Once the display is shown, repeatedly pressing 
the 

Select

 button allows you to set the brightness 

of the display. The brightness level can be set to: 
Off, Dim 3, Dim 2, Dim 1, Normal, Bright 1, 
Bright 2 and Bright 3. Once the Display bright-
ness is at the desired value, press the 

Setup

 

button to store the setting.

AVR Range Function

Allows you to adjust the AVR (Automatic Voltage 
Regulation) system of the RLC-1040. It can be 
set to: Narrow, Normal or Wide.

Narrow AVR Range

 – Takes input voltages 

from 100-132 VAC and regulates it to 120 VAC 
± 5%. Use this setting if the power input voltage 
is fairly stable.

Normal AVR Range

 – Takes input voltages 

from 97-139 VAC and regulates it to 120 VAC 
± 10%. Use this setting if the power input voltage 
has moderate variations

Wide AVR Range

 – Takes input voltages 

from 92-145 VAC and regulates it to 120 VAC 
± 15%. Use this setting if the power input voltage 
has large variations

The “Vin” line of the “Voltage Input/Output” 
display (see preceding page) will show you how 
much the input voltage varies. 

Press the 

Setup

 button until the “SET AVR 

RANGE ?” menu is displayed.

������������������
������������������

Then press the 

Select

 button to change the AVR 

Range setting. After you have selected the AVR 
Range setting you want, press the 

Setup

 button 

to accept the setting.

Delay Time Function

This function sets the amount of time that elapses 
before the RLC-1040 provides power to the rear 
panel outlets marked 

Delayed

. The same amount 

of time will elapse before the RLC-1040 removes 
power to the Delayed outlets.

Press the 

Setup

 button until the  “SET DELAY 

TIME ?” menu is displayed.

������������������
������������������

Then press the 

Select 

button to select the amount 

of delay - from 0 to 12 seconds). Press the 

Setup

 

button to store the setting.

Beeper Function

This function turns the beeper sound on or off. 
When the beeper sound is on, each press of the 

Setup

 or 

Select

 button will be accompanied 

by a beep. 

Repeatedly press the 

Setup

 button to advance 

to the “SET BEEPER ?” menu. 

������������������
������������������

Press the 

Select

 button to toggle the beeper 

between 

ON

 and 

MUTE

. Press the 

Setup

 

button to store the setting.

Language Function

 

This lets you select the language for the LCD 
display. Repeatedly press the 

Setup

 button to 

advance to the “SET LANGUAGE” display. 

������������������
������������������

Press the 

Select

 button to select the language 

– English, French or Spanish.

������������
������������������

������������
������������������

������������
������������������

Press the 

Setup

 button to store the setting.

Summary of Contents for RLC-1040

Page 1: ...Owner s Manual RLC 1040 Power Conditioner...

Page 2: ...ed on the rear panel of the unit Do not use a plug adapter which defeats the ground pin of the AC plug Connect the component to the power outlet only with the supplied power supply cable or an exact e...

Page 3: ...3 English Front and Rear Panel Controls and Connections Rack Ear Mounting...

Page 4: ...stem data lines including COAX and telephone lines With the RLC 1040 all your equipment is protected Isolated Noise Filter Banks The RLC 1040 eliminates electromagnetic and radio frequency interferenc...

Page 5: ...rating The RLC 1040 is capable of supplying the dynamic peak current draws required by any component designed to work on a 15 amp circuit Despite their nameplate power ratings high performance A V equ...

Page 6: ...DIGITAL FILTER outlets any video device can be plugged into either of the VIDEO FILTER outlets etc For example if you have a cable box and a satellite receiver but no monitor you can plug the cable b...

Page 7: ...the rack ears mounted as far back as they can go the front of the RLC 1040 will protrude about 1 from the front of the rack 2 Position the RLC 1040 in the equipment rack so the rack mount ears are aga...

Page 8: ...ltage has large variations The Vin line of the Voltage Input Output display see preceding page will show you how much the input voltage varies Press the Setup button until the SET AVR RANGE menu is di...

Page 9: ...utility power if the power is out of range Probable Cause Circuit Breaker has tripped Solution Check both home and unit circuit breakers If the circuit breaker located on the rear of the RLC 1040 has...