Instruments : DC milli–voltmeter
Notes : Prior to Bias Adjustment, run about 5minutes with rated output(8ohms) and
warm up Power Transistor and Heat Sink. Set input off.
Adjustment
Step
TP1
TP2
X-1426-01 PCB
VR603
VR604
X-1426-01 PCB
1
2
Coupling
Location
Adjust for
Adjust
DC milli–voltmeter reads 4mV
RKB-250
Case Outlines
2SA608K
2SA1016K
2SA1376A
2SC536K
2SC2362K
2SC3478A
2SB631K
2SD1953
2SD600K
2SA1837
2SC4793
2SB817
2SD1047
PC817B
NJM555D
MPC1237HA