5GF DETECTOR USER MANUAL FJC-DL001
Page 6
3. INSTALLATION INSTRUCTIONS
Mounting Detector
The normal installation height from the roadway is 600 mm - 700 mm, the ideal height is 700 mm as this
gives the best coverage. Under no circumstances exceed 800 mm from the ground as low profile sports
cars may not be detected.
The maximum detection distance of 5GF detector is 4 meters. It is recommended that you set the
detection distance 100mm less than the lane width to avoid interference from pedestrians or other
vehicles in adjacent lanes.
Fig.5 Detector Installation Diagram
SETTING UP DETECTOR
1.
Before you power up the detector please ensure there are no objects in the 5GF detection area. If
there are vehicles , people, toolboxes or bollards within the area that you need to protect the
detector will not set up correctly.
2.
When the 5GF detector is connected to the
12vdc supply
, the green light will flicker.
3.
The LCD display will then show a number 3, this shows that the detector is set for a distance of 3
metres. PRESS CH BUTTON
4.
The distance can be adjusted by pressing the CH button then the increase or decrease buttons, the
increments are shown as 0.1 of a metre (100 mm)
5.
When you have checked that the distance is correct PRESS THE ENTER BUTTON. The detector is now
set.
6.
When a person enters the detection area, the green LED of 5GF detector will be on. When the
person leaves the detection area, the green light of 5GF detector goes off, and the boom gate
closes.
7.
When a vehicle enters the detection area, first the green LED switches on then the red LED turns on.
After the vehicle leaves the detection area, the red LED goes off and the boom gate closes.
The default Installation
height of the 5GF detector
is 700 metres from the
ground