2. WIRING INSTRUCTIONS 

 

 

 

 
 

 

 

  

 
 
 

  

  
               

Fig.4 5GF Terminals 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring col-

or 

Output 

Connection 

Note 

Yellow 

Output switch - 

12v- 

5G detector 

output signal n/o  

Pedestrian 

Brown 

Output  

12V+   

Green 

Output switch - 

12v- 

5G detector 

output signal n/o 

Vehicle 

Blue 

Output  

12V+   

Orange 

Not Used 

 

 

Black 

GND 

12vdc - 

Power supply 

Red 

12V+ 

12vdc + 

 

White 

UART TX 

5G detector 
Programmer 
connections 

 

Grey 

UART RX 

 

Black 

GND    

 

Red 

12V+ 

 

CH DETECTION DISTANCE

 

SET DISTANCE

 

INCREASE DISTANCE

 

DECREASE DISTANCE

 

POWER LED

 

COMMAND LED

 

ENTER BUTTON

 

PA 

 

NOT USED

 

Summary of Contents for FJC-DL001

Page 1: ...TECTOR USER MANUAL FJC DL001 Page 1 Vehicle Access Control Pedestrian Access Control Safety Security Equipment SAFEPASS 5GF DETECTOR USER MANUAL V2 0221 T 61 7 3205 1123 www rotech com au e info rotech com au ...

Page 2: ...ces both of these devices offers a superior detection area and is less costly 1 PRODUCT SPECIFICATIONS Fig 1 5GF detector with cable Fig 2 5GF Detector Fig 3 5GF Programmer 5GF Dimensions Product Features 1 The housing is made from ABS material and is waterproof to IP67 2 Detection is achieved using ISM 5 8GHz band and advanced MMIC transceiver this ensures a stable performance and high reliabilit...

Page 3: ...r is mounted directly under the pole and the detection height will be 1 9 metres from the ground The sensor ignores the pole movement only detecting vehicles and people Specification 5GF Detector Construction Material Black ABS Material Size 72mm x 22mm Installation location 600 mm to 700 mm from ground Working frequency band 5 8GHz Temperature 20 70 Humidity 95 no condensation Voltage DC12V Curre...

Page 4: ... Pedestrian Brown Output switch 12V Green Output switch 12v 5G detector output signal n o Vehicle Blue Output switch 12V Orange Not Used Black GND 12vdc Power supply Red 12V 12vdc White UART TX 5G detector Programmer connections Grey UART RX Black GND Red 12V CH DETECTION DISTANCE SET DISTANCE INCREASE DISTANCE DECREASE DISTANCE POWER LED COMMAND LED ENTER BUTTON PA NOT USED ...

Page 5: ...5GF DETECTOR USER MANUAL FJC DL001 Page 5 Wiring Diagram ...

Page 6: ...o protect the detector will not set up correctly 2 When the 5GF detector is connected to the 12vdc supply the green light will flicker 3 The LCD display will then show a number 3 this shows that the detector is set for a distance of 3 metres PRESS CH BUTTON 4 The distance can be adjusted by pressing the CH button then the increase or decrease buttons the increments are shown as 0 1 of a metre 100 ...

Reviews: