16.2.1) Requirements on the intake air ducting
➪
max. length of ducting 500 mm (20 in.)
➪
min. inside dia. at least outside dia. of the intake socket on turbo charger
➪
min. mean bending radius 100 mm (4")
◆
NOTE:
Compression process in the turbo charger will heat up air
considerably, depending on pressure ratio. Usual tempera-
ture rise of 40
°
C (72
°
F) at take-off performance.
■
ATTENTION: High engine performance needs air temperature as low as
possible at turbo air intake. Therefore the air filter should be
located in a recess of the engine cowling or separated from
warm air by partitioning such that via on opening ambient air
can be aspirated.
Air temperature above the limit will automatically reduce boost pressure with
consequent performance loss.
◆
NOTE:
The automatic back off on boost pressure will protect the
engine against damage by overstressing.
Notes regarding too high air temperatures in the air box:
If in case of high intake air temperature the max. air temperature in the airbox is
frequently or permanently above the limit, the arrangement of air intake has to
be improved or an intercooler has to be installed.
◆
NOTE:
Intercooler is not in the supply volume.
Intercooler has to be installed between pressure side of turbo
W
and inlet
E
into airbox.
Requirements on the intercooler:
➪
a minimum flow rate of 300 m
3
/h (390 yd
3
/h) has to be warranted for all
conditions
➪
the pressure loss must not exceed 15 hPa
■
ATTENTION: No additional forces or moments are allowed on turbo
charger or airbox, therefore the intercooler has be supported
independent and free of vibrations.
▲
WARNING:
The certification to the latest requirements such as FAR and
JAR has to be conducted by the aircraft builder.
16.2.2) Airfilter
■
ATTENTION: A minimum flow rate of 300 m
3
/h (390 yd
3
/h) has to be
warranted for all conditions.
The pressure loss must not exceed 5 hPa.
▲
WARNING:
Use only filter elements which will not tend to restrict the flow
when in contact with water.
Summary of Contents for 914 F
Page 5: ...Reference Modification No 0 Page 5 Date 1996 05 10 Install 914 F Blank page ...
Page 13: ...Reference Modification No 0 Page 13 Date 1996 05 10 Install 914 F Blank page ...
Page 29: ...Reference Modification No 0 Page 29 Date 1996 05 10 Install 914 F Blank page ...
Page 37: ...Reference Modification No 0 Page 37 Date 1996 05 10 Install 914 F Blank page ...
Page 39: ...Reference Modification No 0 Page 39 Date 1996 05 10 Install 914 F Blank page ...
Page 45: ...Reference Modification No 0 Page 45 Date 1996 05 10 Install 914 F Blank page ...
Page 53: ...Reference Modification No 0 Page 53 Date 1996 05 10 Install 914 F Blank page ...
Page 61: ...Reference Modification No 0 Page 61 Date 1996 05 10 Install 914 F Blank page ...
Page 66: ...Reference Modification No 0 Page 66 Date 1996 05 10 Install 914 F Blank page ...
Page 71: ...Reference Modification No 0 Page 71 Date 1996 05 10 Install 914 F Blank page ...
Page 83: ...Reference Modification No 0 Page 83 Date 1996 05 10 Install 914 F Blank page ...
Page 102: ...Reference Modification No 0 Page 102 Date 1996 05 10 Install 914 F Leerseite ...