9
Lift Initialization Instructions:
Control Panel Diagram
Remote Controller Panel Diagram
1. The service area must be clear of all personnel before
the vehicle is positioned.
WARNING
Locate lift on level concrete surface with a
minimum strength of 3000 psi.
2. Spotting: Position the vehicle in the location where it is
to be lifted.
Note: See Fig. 6 for the general arrangement of each lift
column.
3. Start Remote Controller:
Press Power button
on Remote Controller for 2
seconds. Remote Controller will prompt for system
ID
S 3
(flashing last used System ID, example S 3).
Change if needed using the menu arrows
, then
select using enter key
. Remote Controller will prompt
for quantity of columns in system
C 4
(flashing last
used quantity, example C 4).
Note: See Fig. 4 for Column display example, see Fig. 5 for
Remote Controller membrane menu display example.
4. Column Placement and Configuration: Remote Controller
directs operator to first column placement position (default
to Front Right). Position one column at a lifting wheel
location. Position so that the forks are under the tire and the
unit is pushed in as far as possible, Fig. 6. Ensure fork width
is adjusted to properly accommodate the tire/wheel size.
Turn on the Power Up Switch, Fig. 7.
5. Column will boot and display will prompt for System ID
S___3
(flashing last used System ID). Change if needed
using the menu arrows
, then select using enter
key
. Column assumes current channel is no response
to menu prompting within 5 seconds.
Column will beep and indicator beacon will flash
indicating successful link to Remote Controller master
controller.
Note: First column configured will beep and flash 1 time,
second column configured will beep and flash 2 times.
6. Remote Controller will now direct operator what column
to position next. Position using loading instructions from
step 4.
7. Repeats steps 4-6 until columns quantity selected in
step 3 have been configured. System will automatically
lock when all columns are configured. After last column is
configured all columns will beep and indicator light will be
turned on to signify ready to lift.
i
HEIGHT
WEIGHT SINGLE / PAIR / ALL
(FLEX MAX ONLY)
FIND
REMOTE
ACCESSORY
LIGHT ON/OFF
MENU
UP
MENU
DOWN
MENU
ENTER
S___3
ACCESSORY
LIGHT ON/OFF
POWER
RESUME
COLUMN LED
INDICATORS
MENU
ENTER
MENU
UP
MENU
DOWN
RAISE/LOWER
BUTTON
LOWER TO
LOCK
S_3
6X COLUMN
BUTTONS
E-STOP
Fig. 4
Fig. 5