background image

7

WARNING  

  

If you are not completely familiar 

with automotive lift maintenance procedures 

STOP: 

 

Contact factory for instructions.

To Avoid Personal Injury, permit only qualified lift 

service personnel to perform maintenance on this 

equipment.

Use only genuine Rotary replacement parts for 

repairs.

•  Always

 keep all bolts tight.  Check periodically.

•  Always

 raise lift when cleaning floor area.

•  Always

 keep lift clean.

•  Daily:

  Inspect adapters for damage or excessive 

wear.  Replace as required with genuine Rotary 

parts.

•  Weekly:

  Inspect all lift parts for signs of damage 

due to overloading and rough handling.

•  Monthly:

  Lightly grease adapter sliding surfaces.

•  Monthly:

  Releave residual pressure in the slave 

cylinders by loosening the slave circuit shut-off 

valves, screws A2 - B2. When complete tighten 

screws A2 - B2.

•  Semi-Annually:

  Check fluid level of lift power unit.   

Refill if required per lift installation instructions.  If 

fluid is required, inspect all hoses and seals.  Repair 

as required.

•  If lift

 stops short of full rise or chatters, check fluid 

level and purge both cylinders per lift installation 

instructions.

•  Replace

 all CAUTION, WARNING, or SAFETY related 

decals on the lift if unable to read or missing.  

Reorder labels from Rotary Lift.

MAINTENANCE  INSTRUCTIONS

Summary of Contents for 300 Series

Page 1: ...FETY INSTRUCTIONS 2 OWNER EMPLOYER RESPONSIBILITIES 3 OPERATING INSTRUCTIONS 4 MAINTENANCE INSTRUCTIONS 6 TROUBLE SHOOTING 7 OM20201 Entire contents May 2010 by Rotary Lift All rights reserved CO7585 1 Rev C 05 06 10 LP20469 RLP35 Scissor Lift 300 Series Capacity 7700 lbs 3500 kg Maximum 3 850 lbs 1750 kg per pad B M W B M W ...

Page 2: ...erload lift Capacity of lift is 7 700 lbs 3500kg 3850 lbs 1750kg per platform Do Not stand in front of the lift or vehicle while it is being positioned in lift bay Before driving vehicle into lift bay BE SURE lift is fully lowered Load vehicle on lift carefully Check for secure contact with vehicle Raise lift to desire working height Do Not block open or override self closing lift controls they ar...

Page 3: ...SI ALI ALOIM 2008 American National Standard for Automotive Lifts Safety Requirements for Operation Inspection and Maintenance and The Employer Shall ensure that lift maintenance person nel are qualified and that they are adequately trained in the maintenance of the lift Shall maintain the periodic inspection and maintenance records recommended by the manufacturer or ANSI ALI ALOIM 2008 American N...

Page 4: ...rformed and the reason for it 2 Unload the subject lift Shut it down and assure the disconnect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power to the sub ject lift If this is a lockable device the authorized lockout person places the assigned padlock on the device to prevent its unintentional reactivation An appr...

Page 5: ...cation of corrosion Vehicle individual axle weight does not exceed 1 2 lift capacity Slide rear pad extension as necessary to reach rear lift points Use auxiliary rubber blocks to create clearance between vehicle chassis and lift pad Fig 4 Auxiliary rubber blocks pads are in secure contact with vehicle manufacture s recommended lift points Vehicle is stable on lift neither front nor tail heavy 3 T...

Page 6: ... the right front door lock face showing specific vehicle lift points If the specific vehicle lift points are not identified refer to the Typical Lift Points illustrated herein ALWAYS follow the operating instructions supplied with the lift Typical Wheel Spotting Position Fig 2 Fig 1 Fig 3 Fig 4 1 Disconnect Switch 2 Raise Button 3 Lower Button ON 1 3 2 A Perimeter Frame Front Front Front Stub Fram...

Page 7: ...all lift parts for signs of damage due to overloading and rough handling Monthly Lightly grease adapter sliding surfaces Monthly Releave residual pressure in the slave cylinders by loosening the slave circuit shut off valves screws A2 B2 When complete tighten screws A2 B2 Semi Annually Check fluid level of lift power unit Refill if required per lift installation instructions If fluid is required i...

Page 8: ...operly installed proximetry Remedy 1 Replace blown fuse or reset circuit breaker 2 Supply correct voltage to motor 3 Repair and insulate all connec tions 4 Check the contactor coil opera tion and make sure it is activated when supplied with 24V 5 Check the fuse on the transform er and replace it if necessary 6 Check the output voltage of the transformer OUT 24V 7 Wait for 10 minutes and try start ...

Page 9: ...s are not level 3 Air is in one of the slave cylinders Remedy 1 Remove the obstacles blocking the lowering phase 2 Check and supply power to lift 3 Check and replace the fuse after eliminating the cause of the short circuit 4 Check the output voltage of the transformer OUT 24V 5 Check to see if valve coils are getting current 6 Unscrew the valves on the hydraulic block one by one and make sure the...

Page 10: ...acles blocking the lowering phase remember that the car lift may not be lifted again to remove possible obstacles Disconnect main power supply Remove manual lowering cap Note Manual lowering emergency operations should be preformed by authorized personnel specially trained for operating the car lift only Loosen the manual operators OM A1 B1 1 2 turn Emergency lowering has started speed can be incr...

Page 11: ...11 6 1 M 5 RF RF 2 4 OM A2 OM A1 OM B1 OM B2 6 3 5 1 Suction filter 2 Pump 3 Breather 4 Relief valve 5 Unidirectional valve 6 Lowering valve OM Manual Operator RF Flow regulator valve M Motor 3 KW ...

Page 12: ...ent Parts See installers package for parts breakdown sheet Order Genuine Rotary replacement parts from your nearest Authorized Parts Distributor Maintenance Assistance Contact your local Rotary distributor Should further assistance be required contact Rotary Lift at one of the phone numbers listed below ...