page 10

Throughout the combustion do not open the door of the base.

It is recommended to make the heater works for the entire duration of the pellet combustion.

The suggested pellet quantity is roughly calculated because the Heater filled with a few quantity of 

pellet produces an higher flame because there is more air inside the burner, but the duration will 

be shorter. On the contrary if the Heater is filled with a big quantity of pellet the duration will be 

longer but the flame will be lower because of the minor quantity of air inside the burner.

When the flame finishes the Heater keep on heating for at least 2 hours depending on the initial 

quantity of pellet which continues to heat also there isn’t open flame.

The Heater can be filled again opening the drawer under the burner, according to the instructions 

at the following points from 7 to 12 (

unload and cleaning operations)

 and then following the 

instructions at the previous points from 3 to 6 (

loading and firing up

) for refuelling the burner with 

additional pellet.  

 

Once the Heater is on, it will work with a pyrolysis process (fig. at page 08) which consists in the 

top-down anaerobic combustion of the pellet. This process will transform the combusted pellet in 

a completely natural compound, that will be easy to dispose of. Anyway, pay attention to the rules 

in force in your country about the separate collection.

Unloading:

7. 

open the door of the base and extract the burner;

8. 

Wearing the appropriated fireproof mitts, remove the top of the ash drawer;

9. 

Keep wearing the fireproof mitts, you have to operate the opening of the part underneath 

the burner so you can drop the combustion residues inside the ash drawer;

10.  Clean the inside of the breazier, using the poker if necessary, removing any residual pellets 

even if still burning.;

11. 

please check that the edges and the lower door are clean so to have a perfect closing; then 

close it;

12.  close the drawer with its cover.

WARNING: THE ASH DRAWER HAS TO BE EMPTIED ONLY WHEN THE COMBUSTION RESIDUES INSIDE WILL BE 

COMPLETELY COLD AND OFF. FOR THE DISPOSAL YOU HAVE TO RESPECT THE RULES IN FORCE IN YOUR COUNTRY 
ABOUT THE SEPARATE COLLECTION

Reload:

When you executed the operations until the previous point 12, the Heater is ready to be used 

again. You have only to repeat the load procedure restarted from the point 3 of the “LOADING AND 

FIRING UP” instructions.

It is reiterated that:

• 

When the Heater is hot, its functioning and status has to be constantly controlled;

• 

The operations on the Heater has to be done always with the standard issue protections and 

taking the necessary precautions to avoid burns.

• 

The temperature and the duration of the flame indicated on the previous schedule of this 

manual and on the Heater’s brochure are purely indicative and they are directly evaluated 

and regulated according to common sense and specific conditions of the Heater’s user and 

what kind of pellet used.

• 

After every ignitions it is recommended to clean well the Heater, to empty the ash drawer 

with the opening under the burner using the attention and care recommended previously. 

The cleaning of the burner can be done both leaving inside the base the burner, opening 

the top of the ash drawer, and extracting the burner and the ash drawer from the Heater. 

Summary of Contents for RUBINO

Page 1: ...user and maintenance manual Rev no 02 25 03 2018 OUTDOOR WOOD PELLET PATIO HEATERS...

Page 2: ......

Page 3: ...nd Installation pag 05 Functioning of the Heater pag 08 Initial Operation pag 08 How to load fire up unload and reload the Heater pag 09 Cleaning and Maintenance pag 11 Operational Problems pag 12 Tec...

Page 4: ......

Page 5: ...acturer is not liable for damages or injury resulting from failure to observe this prohibition WARNINGS This manual is an integral part of the product It must always accompany the heater even in case...

Page 6: ...the glass tube of the model RUBINO as well as the door of the internal brazier of both models must be always closed during the use of the heater so that the key of the door has to be pulled out Please...

Page 7: ...te combustion such as cigarettes or lighted lighters flames of various kinds scintillators 32 do not modify the equipment or perform technical operations that are not authorized by the manufacturer Ea...

Page 8: ...xtent the durability Finally the heater is fitted with an internal collecting drawer underlying the brazier Model DIAMANTE this heater consists of the base element with an internal brazier installed o...

Page 9: ...AND INSTALLATION Remove the packaging and detach the base element the metallic sheating and in particular carefully the glass tube Splice the metallic sheating with the base element using the 4 screw...

Page 10: ...ng above and then has to be deposited on the base element Afterwards splice the stainless steel element and the roof using the 8 screws supplied After the assembly make sure that you have followed all...

Page 11: ...DIAMANTE please attend the following instructions 1 Insert the eight metal supports in the holes tha are at the top of the heater fixing them the screws given 2 Insert each of the four tempered glasse...

Page 12: ...pen the door of the base element during the combustion Let the heater to operate until the pellets in the burner have completely burned bearing in mind that after the diminishing of the flame the heat...

Page 13: ...the glass tube mod RUBINO or inside the area surrounded by the glasses DIAMANTE Especially on the occasion of the first ignition or of those immediately following it is considered normal the emission...

Page 14: ...the fireproof mitts you have to operate the opening of the part underneath the burner so you can drop the combustion residues inside the ash drawer 10 Clean the inside of the breazier using the poker...

Page 15: ...in its place on the base of the Heater 9 close again the heat diffuser door Glasses cleaning mod DIAMANTE 10 it makes sure that there isn t flame and the Heater is cold and off 11 spray the glasses wi...

Page 16: ...this manual and correct possible errors in installation Meticulously follow all instructions The flame don t start up The flame reducer is missing Place the supplied flame reducer on top of the burner...

Page 17: ...UBINO 500x500x1900 mm 55 kg Pyrolitic outdoor heater DIAMANTE 500x500x900 mm 35 kg TECHNICAL DATA CLIMATIC CONDITIONS OF USE Temperature 0 30 C Relative Humidity 10 90 ANALYTICAL PARAMETERS Filling pe...

Page 18: ...OCO s r l unipersonale The legal representative Applicable legislation Directive 2001 95 EC on the general rules of product safety implemented with D Lgs 206 2005 Consumer Protection Law Partl IV Secu...

Page 19: ...l The incomplete coupons or without the stamp and signature of the dealer will not be considered valid WARRANTY CARD part to be filled in and stored by the customer Model Serial number Date of purchas...

Page 20: ...ears from the date of purchase indicated on the back and affixed by the retailer at the time of sale together with its stamp and signature The manufacturer s warranty covers the costs of the spare par...

Page 21: ...page 17...

Page 22: ...page 18...

Page 23: ......

Page 24: ...ction and distribution by ROSSOFUOCO srl unipersonale Via Cavalieri di V Veneto 21 61045 Pergola PU ITALY P Iva 02443170416 tel 39 0721 735926 fax 39 0721 737107 mail info rossofuoco com www rossofuoc...

Reviews: