Rosslare SA-59 Installation And User Manual Download Page 6

Notice and Disclaimer 

vi 

SA-59 Installation and User Manual 

Notice and Disclaimer 

This manual’s sole purpose is to assist installers and/or users in the safe and 

efficient installation and usage of the system and/or product described herein. 

B

EFORE ATTEMPTING TO INSTALL AND

/

OR USE THE SYSTEM

,

 THE INSTALLER AND 

THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY 
REQUIREMENTS AND OPERATING PROCEDURES

 

The system must not be used for purposes other than those for which it 

was designed. 

 

The use of the software associated with the system and/or product, if 

applicable, is subject to the terms of the license provided as part of the 

purchase documents. 

 

ROSSLARE exclusive warranty and liability is limited to the warranty and 

liability statement provided in an appendix at the end of this document. 

 

This manual describes the maximum configuration of the system with the 

maximum number of functions, including future options. Therefore, not 
all functions described in this manual may be available in the specific 

system and/or product configuration you purchased. 

 

Incorrect operation or installation, or failure of the user to effectively 

maintain the system, relieves the manufacturer (and seller) from all or any 

responsibility for consequent noncompliance, damage, or injury. 

 

The text, images and graphics contained in the manual are for the 

purpose of illustration and reference only. 

 

All data contained herein is subject to change without prior notice. 

 

In no event shall manufacturer be liable for any special, direct, indirect, 

incidental, consequential, exemplary or punitive damages (including, 

without limitation, any and all damages from business interruption, loss of 

profits or revenue, cost of capital or loss of use of any property or capital 

or injury). 

 

All graphics in this manual are for reference only, some deviation between 

the image(s) and the actual product may occur. 

 

All wiring diagrams are intended for reference only, the photograph or 

graphic of the PCB(s) are intended for clearer illustration and 

understanding of the product and may differ from the actual PCB(s).

Summary of Contents for SA-59

Page 1: ...SA 59 GSM Communicator Installation and User Manual ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ... 7 2 Technical Specifications 8 3 Installation 9 3 1 General 9 3 1 1 LED Indicators 9 3 1 2 I O Description 9 3 2 Wiring 10 3 3 Mounting 11 4 Messaging Types 12 4 1 SMS Messaging Types 12 5 Programming 13 5 1 Programming the System 13 5 1 1 Prefix Number Programming 13 5 1 2 Phone Number Programming 14 A Limited Warranty 15 ...

Page 4: ...List of Figures iv SA 59 Installation and User Manual List of Figures Figure 1 SA 59 Components 9 Figure 2 Wiring Diagram 10 ...

Page 5: ...List of Tables SA 59 Installation and User Manual v List of Tables Table 1 LED Indicators 9 Table 2 I O Description 9 Table 3 Inputs 11 ...

Page 6: ...erefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in the manual are f...

Page 7: ...the system to which it is connected When the SA 59 is connected to a telephone line Line IN the SA 59 directs the device to a land line to make a call If the land line is cut or not functioning all communications go via the GSM network without the need for any special additional settings If the SA 59 is not connected to a land line all communications take place via the GSM network The SA 59 incorp...

Page 8: ...ollector outputs of 200 mA Relay 1 Form C 1A relay related to Input 1 Telephone Lines Telephone line out and telephone line in LEDs 5 LED indications Connections PSTN Telephone Line IN Connected to the main telephone line in the premises before any other connection Telephone Line OUT Should be connected to the alarm system Environmental Characteristics Operating Temp Range 0 C to 60 C 32 F to 140 ...

Page 9: ... ON Power supply is connected to device D3 Transmission Transmission of signal to antenna D4 Reset Reset in power up D1 GSM Power up ready Power up the device LD21 Dialing telephone device 3 1 2 I O Description Table 2 describes the I O activation Table 2 I O Description Input Activation Input activation triggers the outputs in the following order Input 1 Activate Output 1 Input 2 Activate Output ...

Page 10: ...s so that when the input is set to 0 grounded the output is activated When the input is set to 1 not connected the output returns to its steady state 3 2 Wiring Figure 2 shows the main components on the SA 59 board including terminal blocks and LED indicators Figure 2 Wiring Diagram ...

Page 11: ...input 2 Input 3 Logical input 3 Input 4 Logical input 4 Line OUT Telephone Line OUT from system to telephone device Line IN Telephone Line IN from the entrance point to the system To wire the SA 59 1 Connect Line IN to the phone line and Line OUT to the alarm sytem 2 It is suggested to connect the tamper to the Input 1 and Output 1 to the alarm system to receive an indication of tampering with the...

Page 12: ...by changing the 4th input in the SA 59 4 1 SMS Messaging Types Input Sent Message Input 1 high SYSTEM TROUBLE Input 1 low SYSTEM TROUBLE RESTORE Input 2 high PANIC ALARM Input 2 low PANIC RESTORE Input 3 high SYSTEM ARMED Input 3 low SYSTEM DISARMED Input 4 high SYSTEM ALARM When system indicates SYSTEM TROUBLE the input has switched from 0 V connected to ground to a non connected state tri state ...

Page 13: ... is not connected to PSTN lines The default installer code is 5555 5 1 1 Prefix Number Programming When using the GSM network the addition of a prefix number may be needed The prefix number is user programmable To program the prefix number 1 Press 5555 to enter Program mode 2 Press 1 3 Type the prefix number 4 Press to confirm The unit beeps Example For prefix number 9 press 5555 1 9 To delete the...

Page 14: ...mber 4 Press to confirm The unit beeps Example For number 052646666 press 5555 2 052646666 To program additional phone numbers 1 Press 5555 to enter Program mode 2 Press 3 For the third phone number Press 4 instead of 3 3 Type the prefix number 4 Press to confirm The unit beeps Example For the number 052525222 press 5555 3 052525222 To delete phone numbers 1 Press 5555 to enter Program mode 2 Pres...

Page 15: ...mited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 16: ...osslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electron...

Reviews: