Editing a Panel Account
HomeLogiX™ HLX-40 Software Manual
33
Section
Property
Item
Description
Hide Display
If On, HR-P02 hides its status display when armed,
and shows only the prompts. The options are: On
and Off.
Key Beeps
If On, each time a key is pressed on the panel
keypad, you hear a key beep. The options are: On
and Off (default).
Instant Arm
If enabled, HR-P02 may be instantly armed by
bypassing the Exit Delay. The options are: Enabled
and Disabled (default).
Language
Defines the system language for both textual
messages and audio feedback. The options are:
English (default), Spanish, Portuguese, and Greek.
Note that for Greek, the display shows the Greek
language in Latin characters, while the audio
feedback is in Greek.
CP-01
Settings
Recent to close
time
A central station event is sent if the defined time
passed after the exit delay countdown.
The Default is: 2 minutes
Swinger
Shutdown Time
Duration for automatic resetting of detectors after
being ignored by swinger trips.
The default is 8 hours.
Abort
Annunciation
Aborts transmission to central station in the LCD
during alarm.
The default is Enabled
Cancel
Annunciation
Cancels transmission to central station in the LCD
during alarm.
The default is Enabled
Fire Verification
Fire verification double checks the state of the fire
detectors.
The default is Disabled.
EN CENELEC
Setting
Status
Enable or disable the CENELEC standard settings.
Event Filter
Counter
Counts the number of event filters. An event filter
enables the user to specify the maximum repetition
of a specific event in a session.
Access Memory
Enable/disable code access to view previous alarms
in memory.
Access System
Status
Enable/disable code access to view system status.
Access Alarm
Instant
Enable/disable need to re-enter code for instant
arming.
Low Battery
Enable/disable arming the panel when a low battery
fault exists.
Power Fail
Enable/disable arming the panel when a power
failure fault exists.