Controller Functionality
AYC-x6355 (Rev. B) Installation and User Manual
37
7.
Controller Functionality
Upon power on or reset, the unit flashes red, then green, and then
orange, each for 1 second and a beep is heard for each color. The
unit searches for the presence of Rosslare's secured intelligent power
supply. If a secured intelligent power supply is detected, the buzzer
emits 2 short beeps and the unit is automatically configured as a
secure access control unit. The LED returns to its idle state – either
green (Normal mode), red (Secure mode), or orange (Bypass mode).
The Lock Strike and Auxiliary outputs, as well as the REX input, are
not located on the unit, eliminating the possibility of unauthorized
entry to the restricted area.
7.1
Normal, Secure, and Master Users
The unit accepts up to 500 users and provides entry via the use of PIN
codes and/or proximity cards. Each user is provided with two code
memory slots, Memory Slot 1 (Primary code) and Memory Slot 2
(Secondary code).
The PIN code length has several options. The PIN code length can be a
set number of 4, 5 or 6 digits or it can be a 4–8 digits option. When
choosing the 4- to 8-digit option, please note that you should either
enter zeros before the code, or press pound at the end (for example,
if your code is 12345, enter either
00012345
or
12345#)
.
Entering a code refers to either PIN or proximity card.
The way in which the two memory slots are programmed determines
a user’s access level and also determines the way in which the unit
grants access in its three modes of operation. There are three user
levels:
Normal
A Normal user only has a Primary code and is only granted access
when the unit is in Normal or Bypass mode.