Reader Functionality
AYC-E/Q/T60 Family Installation and Programming Manual
33
•
The Programming code cannot be erased; the code 0000 is invalid
and does not erase the Programming code.
•
The factory default 4-digit Programming code is 1234.
5.2.8
Changing the Facility Code
To change the Facility code:
1.
Enter Programming mode.
2.
Press
4
to enter Menu 4.
The Transmit LED turns red.
3.
Enter the new 3-digit code you
wish to set as the Facility code.
You hear three beeps.
The system returns to Transmit
mode.
•
The Facility code can be in the range of 000 to 255.
•
The default Facility code is 0.
5.2.9
Setting the Backlight Behavior
To set the backlight behavior:
1.
Enter Programming mode.
2.
Press
6
to enter Menu 6.
The Transmit LED turns red.
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Red
Green
Mode/Transmit
Door/Program
Red
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Red
Green