Reader Functionality
AYC-E/Q/T60 Family Installation and Programming Manual
27
If
*
or
#
are pressed during PIN code entry, the keypad clears the PIN
code entry buffer, generates a beep, and is ready to receive a new 4-
digit keypad PIN code.
If the entry of the 4-digit keypad PIN code is disrupted and no number
key is pressed within 5 seconds, the keypad clears the PIN code entry
buffer, generates a beep, and is ready to receive a new 4-digit keypad
PIN code:
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP)
Where:
EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
F = 8-Bit Facility code
A = 16-Bit code generated from keyboard
5.2.4.5
Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
Option 5 buffers up to 5 keys and outputs keypad data with a Facility
code like a 26-bit card output.
The Facility code is set in Programming Menu 4 and can be in the
range 000 to 255. The factory default setting for the Facility code is
000 (see Section
5.2.8 for more information). The keypad PIN code
can be one to five digits in length and can range between 1 and
65,535. When entering a keypad PIN code that is less than 5 digits in
length,
#
must be pressed to signify the end of PIN code entry. For
keypad PIN codes that are 5 digits in length, on the fifth key press of
the 5-digit PIN code, the data is sent across the Wiegand Data lines as
binary data in the same format as a 26-bit card.
If
*
is pressed during PIN code entry or a PIN code greater than
65,535 is entered, the keypad clears the PIN code entry buffer,
generates a beep and is ready to receive a new 5-digit keypad PIN
code.
If the entry of the 1- to 5-digit keypad PIN code is disrupted and a
number key or
#
is not pressed within 5 seconds, the keypad clears
the PIN code entry buffer, generates a medium length beep, and is
ready to receive a new 1- to 5-digit keypad PIN code: