background image

How to Use the Reader 

18 

AY-M26 Installation and Configuration Manual 

5.2

 

Manual LED and Buzzer Control 

LED and buzzer behavior depend upon the reader firmware. For 
example, three beeps on reset and successful configuration, or one 

short beep and a flashing LED upon card transmission. However, it is 
possible that the host control panel, to which the reader is connected, 

may control the LED, the buzzer, or both. This depends upon 

manipulation of the LED/buzzer control input, and only if these 
options are enabled by the reader configurations. 
These settings can be overridden using the brown LED/buzzer control 
wire: 

 

LED/buzzer control wire is left open: 

 

LED and buzzer behave naturally based on firmware 
preferences 

 

LED/buzzer control wire is connected to ground: 

 

If the LED control is enabled, the LED turns green 

 

If the buzzer control is enabled, the buzzer continuously 

buzzes 

 

If both LED and buzzer control are enabled, the led turns 

green and buzzer contentiously operated. 

Use the LED/buzzer control wire to determine the behavior of the LED 

and buzzer directly from the access control software. 

 

LED and buzzer control function can be only programmed by 

Configuration card. They cannot be programmed using the 
reader keypad. 

5.3

 

Optical Back Tamper 

The AY-M26 includes an optical back tampering mechanism that 
detects all attempts to dismantle the unit or remove it from the wall. 
The status of the tamper mechanism is indicated by the purple tamper 
control wire. 
When the back tamper optical sensor is in “darkness” status, the 

internal tamper output transistor is pulled to low. 

Summary of Contents for AY-M26

Page 1: ...AY M26 MIFARE Sector Reader Installation and Configuration Manual ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...he Reader 10 3 2 Installation Kit 10 3 3 Installing the AY M26 Reader 11 3 4 Wiring Instructions 12 4 Configuring the Reader 14 4 1 Operation Modes 14 4 2 Configuration Card Structure 15 4 3 Configuring Settings 15 4 4 Configuring the Reader 16 5 How to Use the Reader 17 5 1 Normal Operation 17 5 1 1 Card Serial Number Mode 17 5 1 2 Secure Mode 17 5 2 Manual LED and Buzzer Control 18 5 3 Optical B...

Page 4: ...List of Figures iv AY M26 Installation and Configuration Manual List of Figures Figure 1 Removing the Top Cover 11 Figure 2 Connecting the Reader to an Access Control System 13 ...

Page 5: ...List of Tables AY M26 Installation and Configuration Manual v List of Tables Table 1 Wiring Colors 12 ...

Page 6: ...ure options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in th...

Page 7: ...trol system The reader can also check the validity of cards before scanning them When checking the reader only sends card information to the access control system from cards with the correct security pass code The readers are suitable for both indoor and outdoor installations Reader setup and operation is controlled using a Configuration card to adjust settings directly without having to connect a...

Page 8: ...de or Card Serial Number mode Pre validation of smart cards by secure pass code Configured directly and easily using configuration smart cards Suitable for indoor and outdoor use fully potted and IP65 compliant Built in anti tampering security system Multiple programmable card transmission formats Dedicated LED and buzzer control input 1 3 Supported RFID Transponders The AY M26 reads the following...

Page 9: ...le Proximity Read Range 45 mm 1 8 in Operating Frequency 13 56 MHz Transfer Bit Rate 106 Kbits per second Output Indicators One tri colored LED buzzer Card Compatibility MIFARE and all ISO14443A 3 cards Card Transmit Formats Programmable Environmental Characteristics Operating Temp Range 31 C to 63 C 25 F to145 F Operating Humidity Range 0 to 95 non condensing Operating Environment Water resistant...

Page 10: ...ed surface and connect it to the access control system 3 1 Unpacking the Reader Confirm receipt of all items listed below before installing If any items are missing contact your dealer immediately One reader This manual Installation kit including One self adhesive drilling template One security spline key One security hex key Two mounting screws Two wall plugs 3 2 Installation Kit The installation...

Page 11: ...he cable If mounting on metal place a grommet or electrical tape around the edge of the hole 6 Route the interface cable from the reader to the controller A linear type power supply is recommended 7 Remove the reader s snap off front cover to reveal the two screw holes see figure below Figure 1 Removing the Top Cover 8 Align the two holes of the reader with those drilled in the wall and firmly att...

Page 12: ...power supply or a common ground with the access control system To connect the reader to the controller 1 Remove 32 mm 1 of the reader cable s insulation jacket 2 Strip 13 mm of the insulation from the wires 3 Splice the reader s pigtail wires to the corresponding input wires for the access control system as listed in Table 1 and shown in Figure 2 Table 1 Wiring Colors Color Function Red DC Input B...

Page 13: ...with insulating tape and then trim and cover all unused connectors To shield the cable from external interference attach it to one of the following The same earth ground as the access control system The signal ground connection at the panel The power supply end of the cable AY M26 Standard Access Control System with Wiegand Reader Keypad Interface ...

Page 14: ...01 must be used to set up configuration cards 4 1 Operation Modes The readers operate in two modes Card Serial Number mode The reader scans every card and sends each card s serial number CSN to the access control system This card serial number is unique for each card In this mode keypad programming is enabled and can be used to program some reader settings In some circumstances not all serial numb...

Page 15: ...IFARE 1K MIFARE 4K and DESFire cards are supported MIFARE Ultralight cards are non functional 4 2 Configuration Card Structure MIFARE smart cards are split into multiple sectors on a MIFARE 1K card for example Each sector contains 4 blocks of 16 bytes each The information on how to program and configure readers is stored in sector zero of the configuration smart card Refer to the CP R25 or CP R26 ...

Page 16: ...he reader LED is orange as the reader goes into Configuration mode 2 Within 30 seconds while the reader is still in Configuration mode present a valid Configuration card to the reader If the configuration is valid three short beeps are emitted and the reader LED turns red If configuration fails due to a bad Configuration card three long beeps are generated and the reader exits Configuration mode I...

Page 17: ... If the card serial number is not fully transmitted only the LSB portion of the serial number is transmitted This depends on the reader transmit format of the selected reader and the length of the card serial number For example when the Wiegand 26 bit transmit format is selected the MSB byte of the MIFARE 1K card s serial number is not transmitted 5 1 2 Secure Mode In this mode the reader attempts...

Page 18: ...d on firmware preferences LED buzzer control wire is connected to ground If the LED control is enabled the LED turns green If the buzzer control is enabled the buzzer continuously buzzes If both LED and buzzer control are enabled the led turns green and buzzer contentiously operated Use the LED buzzer control wire to determine the behavior of the LED and buzzer directly from the access control sof...

Page 19: ...der AY M26 Installation and Configuration Manual 19 When the back tamper optical sensor is in its lit status the internal tamper output transistor s collector is open A tamper signal is detected by the host control panel ...

Page 20: ... A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 21: ...osslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electron...

Reviews: