LOCK1 OPEN TIME
3.8.1.2.
It sets the time to give the signal when LOCK 1 sets
2. STRIKE/OK
. Strike type means the
time from opening to locking the door after authenticating.
The default value is 3 seconds and
the input range is 1 to 20 seconds.
LOCK2 type
3.8.1.3.
NONE
When not using
FAIL IND
When connecting the light to mark authentication failure in Lock 2
MOTOR2
When connecting motor lock
LOCK2 OPEN TIME
3.8.1.4.
If Lock 2 sets FAIL IND, it sets the time to give the signal.
The default value is 3 seconds and the
input range is 1 to 20 seconds.
OPEN ALARM
3.8.1.5.
When the door open time expires and the door open alarm time is exceeded, the alarm sounds.
The default value is 5 seconds and the input range is 0 ~ 20 seconds. If it is set to 0, it does not beep. If
it is set to 1 ~ 20 seconds, it does beep.
Door open time
Open alarm time
DOOR OPEN state
alarm