Programming the AC-A4x
AC-A4x Installation and Programming Manual
37
The controller is now waiting for the Primary code of the user you
want to delete.
4.
Present the Proximity card or enter the 4-
digit PIN code of the Primary code
belonging to the user you want to delete.
The Mode LED flashes red.
5.
Enter your Programming code to confirm the deletion.
If the Programming code is valid, three beeps are emitted and the
unit returns to Normal mode.
If the Programming code is invalid, a long beep is emitted and the
unit returns to Normal mode.
It is recommended that a record be kept of added and deleted
users so that it is easier to keep track of which user slots are
empty and which user slots are not.
11.12
Lock Strike Relay and Auxiliary Relay Code
Assignment
When a Primary code is enrolled for any user, that user is assigned
rights to activate the Lock Strike Relay when a valid code is presented
to the controller. The Code Assignment menu allows you to assign
whether the Lock Strike Relay and/or the Auxiliary Relay is activated
when a user enters a valid code.
There are two methods to assign relay codes to users: a standard
method and a search method.
Mode
Door
Red
Orange