Programming the AC-A4x
AC-A4x Installation and Programming Manual
31
11.9
Setting Fail Safe/Secure Operation, Tamper
Siren Time, and Lock Strike Release Time
1.
Enter Programming mode.
Press
6
to enter Menu 6.
The Mode LED flashes green.
2.
Construct the 4-digit code using the
following instructions:
First Digit
For Fail Secure Operation, the first digit should be
0
.
For Fail Safe Operation the first digit should be
1
.
Second Digit
Tamper Siren time in minutes (1–9)
Third and Fourth Digits
Enter the number of seconds (from 1 to 99) that you want
the Lock Strike to be released.
For example,
0512
means a Fail Secure Operation consisting
of a 5-minute siren and a 12-second Lock Strike release time.
The system returns to Normal mode.
You hear three beeps.
The Door LED turns off and the Mode LED
turns green.