AC-825IP Hardware Settings
AC-825IP Hardware Installation and User Guide
39
5.
AC-825IP Hardware Settings
Access control panels, configured as either single reader door or double reader
door controllers, have two readers, IN or OUT.
Expansion boards attached to the expansion slot of the panel must be
configured the same as the panel (single or double door).
Expansion boards connected via RS-485 standard can be configured
independently of the panel.
When configuring two readers per door, the two readers connected to a door
must be using the same format (OSDP or Wiegand).
Table 2: Possible Hardware Settings
Connectors Description
Setup
Two Readers per Door:
Outputs
Door 1 Lock output
(OUT 1)
Door 2 Lock output
(OUT 3)
Door 3 Lock output
(OUT 5)
General purpose output
(OUT 2)
General purpose output
(OUT 4)
General purpose output
(OUT6)
Inputs
Door 1: Request-to-Exit
(IN 1A)
Door monitor input
(IN 1B)
Door 2: Request-to-Exit
(IN 3A)
Door monitor input
(IN 3B)
Door 3: Request-to-Exit
(IN5A)
Door monitor input
(IN5B)
Readers
Reader1 – Door1
Door Entry or Exit
Reader2 – Door1
Door Exit or Entry
Reader3 – Door2
Door Entry or Exit
Reader4 – Door2
Door Exit or Entry
Reader5 (OSDP) – Door3
Door Exit or Entry
Reader6 (OSDP) – Door3
Door Exit or Entry
One Reader per Door:
Outputs
Door1 Lock output
(OUT 1)
Door2 Lock output
(OUT 2)
Door3 Lock output
(OUT 3)
Door4 Lock output
(OUT 4)
Door5 Lock output
(OUT 5)