AC-425 Hardware Settings
AC-425 Hardware Installation and User Manual
33
Off
–
Defines using two readers for each door. Panel controls two or four
doors when MD-D04 is installed.
On
–
Using one reader for each door. Panel controls four doors or eight
doors when MD-D04 installed.
5.4
AC-425 Panel Address
The last 5 DIP switches are used to set the binary code of the access control
panel internal network address.
The default access control panel address is “1”.
Figure 19: DIP Switch with Internal Network Address Setting
For successful communications, the DIP switch must match the address set in
the AxTraxNG software.
Table 3 displays the 32 address settings available:
Table 3: Available Panel Addresses
Address
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
1
Off
Off
Off
Off
Off
2
Off
Off
Off
Off
On
3
Off
Off
Off
On
Off
4
Off
Off
Off
On
On
5
Off
Off
On
Off
Off
6
Off
Off
On
Off
On
7
Off
Off
On
On
Off
8
Off
Off
On
On
On
9
Off
On
Off
Off
Off
10
Off
On
Off
Off
On
11
Off
On
Off
On
Off
12
Off
On
Off
On
On
13
Off
On
On
Off
Off
14
Off
On
On
Off
On
15
Off
On
On
On
Off
16
Off
On
On
On
On
17
On
Off
Off
Off
Off
18
On
Off
Off
Off
On
1 2 3 4 5 6 7 8