![Rossato Air Combo 200 Technical Manual Download Page 9](http://html1.mh-extra.com/html/rossato/air-combo-200/air-combo-200_technical-manual_1489085009.webp)
2.3 Technical data
u.m.
Air Combo 200-300
Performances
Average COP*
> 3,5
HP yield heat power
*
kW
2,03
Total heat power
*
3,23
Electrical data
Power supply
V/Hz
230/1/50
Maximum absorption HP
kW
0,63
Absorption of e- HP
kW
1,83
Electric heater (integration)
kW
1,20
Delayed action fuse
A
8
Motor protection
NTC
Operating temperatures
Minimum temperature
°C
-10
Maximum temperature
°C
50
Max temp. DHW only HP
°C
65
Max temp. DHW with e-heater
°C
90
Compressor
High efficient reciprocating hermetic
Evaporator
Battery for high heat exchange with aluminium finned coil with
hydrophilic treatment and copper tubes
Test pressure
kPa
3.000
Fan
tangential
Diameter
mm
190
Fan rotation rate RPM
300÷1300
Power
W
25/67
Condenser
Copper pipe
Nominal air flow
m
3
/h
350
Max available head
Pa
30
Refrigerant
R134a
Charge
g
370
Dimensions
Dimensions
Dimensions
Dimensions
Dimensions
Air Combo 200
Air Combo 200
Air Combo 300
Storage tank
Carbon steel with 2 hands vitrification (DIN 4753-3 and UNI
10025)
Carbon steel with 2 hands vitrification (DIN 4753-3 and UNI
10025)
Carbon steel with 2 hands vitrification (DIN 4753-3 and UNI
10025)
Capacity
l
225
295
295
Auxiliary coil
m
2
1,5
1,5
1,5
Insulation
High density foamed PU insulation
High density foamed PU insulation
High density foamed PU insulation
Defrosting
hot gas
hot gas
hot gas
Dimensions
(ø x h)
mm
640 x 1.590
640 x 1.890
640 x 1.890
Weight
kg
118
127
127
*Room air temp.: 20°C; R.H.: 70%; inlet water temp.: 15°C (according to UNI 16147)
Air Combo - installation, use and maintenance manual
AIRCOMBO_TEC_EN_4.07
Page 9 of 28
Rossato Group Srl