10 • Panel Row Module Cabling
Panel Row Module Cabling
To install the cables for the modules, you must first connect the Module Power
cables, and Module Control Link cables.
Memory, Transition, and Keyers Module Cabling
Use the following procedure to cable the Memory, Transition and Keyers
modules:
1.
Connect and secure the existing
Module Control Link Cable
to the
PREV
port on the first module
c
). This CAT5e cable with
an RJ-45 connector on either end is already installed in the control
panel.
Figure 6 Module Control Link Cable — Vision 2X
2.
Connect and secure one of the
Module Control Link Cables
to the
NEXT
port on the first module
c
.
3.
Connect and secure the other end of the
Module Control Link Cable
to the
PREV
port on the second module
d
.
4.
Connect and secure the other Module Control Link
Cable
to the
NEXT
port on the second module
d
.
5.
Connect and secure the other end of the Module Control Link
Cable
to the
PREV
port on the third module
e
.
6.
Connect and secure the existing
Module Power Cable
to the
Power
connector on the first module (
). This 4-conductor ribbon
cable delivers power to all the modules in the row.
1
2
3
Front of Control Panel
Module Control Link Cable