Pull the starter grip lightly until 

resistance is felt, then pull rapidly. 

Repeat until the engine starts.

• 

Push the choke lever to the OPEN 

position as engine warms up. 

The choke is used to provide the proper 

mixture when the engine is cold. It can 

be opened and closed by operating the 

choke lever manually. Move the lever to 

the closed position to enrich the mix-

ture for cold starting.

• 

Once the generator’s engine is 

running, allow several minutes for 

the motor to warm up and stabilize 

before connecting any load. 

• 

Set the main AC circuit breaker in 

the ON position.  Power will now be 

available at the output sockets.

OR

• 

Turn the engine key switch to the START 

position and hold it there until the engine 

starts.

NOTE

: If the engine fails to start after 5 sec-

onds, release key and wait 10 seconds before 

attempting to start again. Cranking the electric 

starter for more than 5 seconds continuously 

can overheat and damage the starter motor.

• 

If your generator has remote starting feature the remote control can also be 

used to start the   generator

NOTE:

 When the generator is new the battery may need to be charge before  can use the 

electric start.  Start the generator manually to charge the battery

NOTE: 

If the engine does not start check the oil level. The engine is fitted with 

and oil sensor that will prevent the engine from starting if the oil level is low.

Summary of Contents for RPG6250RCD

Page 1: ...all safety information warnings and cautions Failure to comply with instructions could result in personal injury and or damage to product or property Please retain instructions for future reference G...

Page 2: ...rnator Regulation Distortion THD Protective Breaker DC OUTPUT Voltage Maximum Current Noise Noise Lwa Wheel size Weight SPECIFICATIONS RPG6250RCD Air Cooled 4 stroke 13 0Hp 389cc 25L Recoil Electric R...

Page 3: ...to generator at gas station use approved container to transfer fuel Ensure there are no fuel leaks and keep sources of sparks and flames away ALWAYS KEEP A CORRECTLY RATED FIRE EXTINGUISHER NEARBY SAF...

Page 4: ...rly tightened Check for fuel leakage while refuelling and during operation If a fuel leak is suspected do not start or run the engine until leak is fixed and spilled fuel has been wiped away WARNING T...

Page 5: ...rown out of standard by this practice endangering attachments and the user Store the generator in a well ventilated area with the fuel tank empty WARNING THE GENERATOR MUST CORRECTLY EARTHED Please re...

Page 6: ...er 7 Outlet sockets 8 Negative 12V terminal 9 DC 12V overload 10 Positive 12V Terminal 11 Engine ON OFF START switch 12 Oil warning light 13 Recoil start handle 14 Earth Terminal 15 Starting Battery 1...

Page 7: ...ls and feet as shown Make sure the battery is se cure mounted in the battery compartment and is held in place by the straps Attach the Black cable to the negative of the battery and firmly tight en th...

Page 8: ...eck without screwing it in then remove it If the level is below the lower level line add the oil until the level reaches the upper mark on the dipstick ADDING FUEL CAUTION USE FRESH UNLEADED FUEL PETR...

Page 9: ...e generator Keep children and pets away from the generator GROUNDING The faceplate of your generator is marked with the following grounding symbol which is located next to the grounding terminal Pleas...

Page 10: ...ow be available at the output sockets OR Turn the engine key switch to the START position and hold it there until the engine starts NOTE If the engine fails to start after 5 sec onds release key and w...

Page 11: ...d to remotely Start and stop the generator The remote has a maximum range of 50 Metres The actual range will vary depending on the situation at hand Obstruc tions position of the generator and conditi...

Page 12: ...urge protector Computers televisions and stereo equipment can be very sensitive to the input supply and could be damaged if protective equipment is not used in conjunction with this generator This als...

Page 13: ...ake sure that all labels are present and legible Check that all protective guards Verify the proper level of the engine oil Inspect the fuel line for defects Inspect the fuel tank cap Make sure it is...

Page 14: ...the oil pan or other suitable container 5 Using a clean cloth wipe off any dirt from the drain plug and filter cap then retighten the drain plug 6 Refill with the recommended oil and check the oil lev...

Page 15: ...enerator on a flat level surface 3 Remove the spark plug cap Clean any dirt or debris from around the spark plug base 4 Use a 13 16 spark plug socket wrench to loosen and remove the spark plug 5 Inspe...

Page 16: ...TROUBLE SHOOTING...

Page 17: ...by loosening the drain screw Drain fuel into a suitable container 8 Remove the spark plug cap and pour a tablespoon of clean engine oil into the cylinder A tablespoon approximately 15 mL Put a clean c...

Page 18: ......

Page 19: ......

Page 20: ...service become necessary during the warranty period the purchaser should contact an Authorised Service Centre or J W Ross In order to obtain warranty service the purchaser must present the store rece...

Reviews: