![Ross NK-RP1 Series User Manual Download Page 16](http://html1.mh-extra.com/html/ross/nk-rp1-series/nk-rp1-series_user-manual_1488929016.webp)
16 • Physical Installation
NK-RP1 Series User Guide (v2.0)
To connect the power cables to the NK-RP1 Series
1. Connect the female end of one provided AC power cable into the socket marked
PSU-A
.
Figure 3.1 NK-RP1 Series — Power Connections
2. Connect the remaining power cable into the socket marked
PSU-B
.
3. Connect each supplied power cable’s three-prong male connector to Mains Power.
Powering Routers and Devices from the NK-RP1 Series
There are two power supply connectors located on the NK-RP1 Series rear panel. Depending on the router or device
being connected, one of two cables will be used: a cable with a DB9 connector or a cable with a Neutrik®
speakON® connector.
Ross NK Devices with a DB9 Connector
The NK-D12/PN has a Phoenix connector on one end to connect to the NK-RP1/P or NK-RP1/PN, and a DB9
connector on the other to connect to a router or control device.
Figure 3.2 NK-D12/PN Cable with a DB9 Connector
The following routers use the DB9 connector for power:
• All NK-164 routers
• All NK-16 routers
• All NK-32 routers
• All NK-34 routers
Caution
— Do not exceed 100W total power for all connected devices. Damage can occur and the
NK-RP1 Series will not be able to supply redundant power if the 100W limit is exceeded. Refer to the
appropriate user guide for the maximum power consumption of each device, or contact Ross Video
Technical Support.
PSU-B
PSU-A
Alarm GPI