background image

© 2017 CHARLES ROSS & SON COMPANY

5

SAFETY FEATURES

1. Safety limit switches and/or proximity sensors.

  For all machines equipped with raise/lower devices,

removable mix cans or other similar features, safety limit switches or proximity sensors are provided.  These
switches or sensors are required to be connected to the control systems in such a manner that will prevent
operation of the machine when the machine is in the raised (non-operational) position and/or the mix can is
removed and/or other safety features are not installed properly.

2. Guards and safety grating.

  All rotating parts or moving parts that may create the possibility of injury are

protected by guards and/or safety grating.  These guards or safety gratings are usually bolted in place to
allow access for periodic maintenance.  Guards and gratings may not always be installed with safety limit
switches or proximity sensors therefore, it is the responsibility of the owner and operator to ensure that these
devices are properly installed prior to operation.

3. Electrical Controls. 

All electrical control panels are built to meet the National Electrical Code at the time

of manufacture and are provided with disconnects that shut off power to the control circuits when the control
panel is open.  Fuses and thermal overloads are provided to protect the control circuits, motors and other
components from overloads.

4. Raise/Lower Controls.

  Many machines are equipped with air/oil hydraulic pistons or electronic/motorized

hydraulic lift systems which will raise/lower the mixer shafts, drive systems, mix cans or discharge platens into
and out of the mixing, discharge or operational position.  On machines where the operator may be allowed within
close proximity to the rotating shafts, discharge platens or pinch points, two (2) hand operator controls
(momentary spring return and/or push buttons) are provided to keep both of the operators hands away from the
dangerous areas during operation of the lift systems.

5. Emergency stop buttons.

  Emergency stop buttons (push/pull mushroom) are provided on all operator

control panels to allow for emergency shut down of the machinery.  These buttons will stop the machinery in
its current position although shafts and drives will drift/coast to a stop.

Summary of Contents for CDA-10

Page 1: ...N COMPANY 1 CHARLESROSS SONCOMPANY CHARLES ROSS SON COMPANY 710 OLD WILLETS PATH HAUPPAUGE NY11788 PHONE 631 234 0500 FAX 631 234 0691 www mixers com CDA DUALSHAFTMIXER CDA 10 INSTALLATION MAINTENANCE...

Page 2: ...UPLE THERMOWELL 9 H GROUNDING CABLES 9 OPERATION 10 A HYDRAULIC LIFT 10 B MIX CAN 10 C VARIABLE SPEED CONTROL 10 D MIXING 10 E VACUUM MIXING 11 MAINTENANCE 12 A AGITATOR SHAFT SEALS VACUUM RATED MIXER...

Page 3: ...fety controls or other safety devices provided with the equipment must be in place and operational prior to operation of the equipment All rotating and or moving parts must be guarded during operation...

Page 4: ...ve or the factory immediately E Mail Fax or Mail a copy of the inspection report and the delivery receipt indicating the problem areas at the time of delivery to sales mixers com Charles Ross Company...

Page 5: ...Electrical Controls All electrical control panels are built to meet the National Electrical Code at the time of manufacture and are provided with disconnects that shut off power to the control circui...

Page 6: ...d orreconditioningtherentedunit thecustomermust include the MSD sheet s of the material s that have been mixed in the rented unit The MSD sheet s are to be returnedwiththe rentedunit IftheMSDsheet s i...

Page 7: ...e hydraulic lift cylinder in two directions at 90 degrees to each other front 0 degrees and side 90 degrees of the hydraulic lift cylinder This should provide a relatively vertically leveled installat...

Page 8: ...ck the rotation of the shaft by jogging the drive motor Correct shaft rotation will be clock wise If the direction is reversed Lockout all power to the controls and reverse the connection of any two o...

Page 9: ...ith oil NEVERALLOWTHESE SEALSAND BEARINGSTO RUN DRY Check the oil level at the oil gauge sight on the side of the bearing housing tower and add oilasnecessarytokeepthissight gaugefullatthecenterline U...

Page 10: ...e Hydraulic Cylinder or on Base Extensions which are at the floor level Appropriate grounding cables should also be attached to the Mix Can C VARIABLE SPEED CONTROL 1 The speed of the agitators can be...

Page 11: ...ncrease the evaporation of other volatiles such as solvents or wetting agents The reaction of each formula to vacuum is different and should be closely monitored during trial runs The horse power requ...

Page 12: ...the shaft surface to its original 240 grit finish This is done by using 240 grit sand paper and then finish using a White Scotch Brite Hand Pad 7445 The shaft surface should appear as new with all scr...

Page 13: ...Dry Running Flexi Lip Sealsand an ATMOSPHERIC RATED MIXER withoutseals are lubricated by grease and should be greased regularly or at least every 500 hours If a bearing makes anunusual noise orruns un...

Page 14: ...per needs to be replaced 1 Pulloutthe oldwiperand thoroughly clean thegroove 2 Gentlytap the new wiperintothe groove witha fiber hammer alap jointwillresult 3 Pull out both ends of the joint fit the e...

Page 15: ...isnotimportant Also refertotheVendorLiteratureformorespecific information 1 Reducer SyntheticAGMAlubricant 7EPor 8EP ISO ASTM viscosity grade 460 680 2 Bearings Anyhightemperature solvent resistant sy...

Page 16: ...Valve 3 way 1 19 Hydraulic Control Valve Hand 1 20 Exhaust Muffler 1 21 Hydraulic Cylinder 5 Dia x 20 Stroke 42 OAH 1 22 Wiper Hydraulic Cylinder 1 23 Packing Gland Hydraulic Cylinder 1 24 Packing Ch...

Page 17: ...Cap 1 58 Mechanical Seal Disperser Single Rotary Complete w 58a 1 58a Mechanical Seal Disperser Single Stationary Complete w 58 1 58b Lip Seal Teflon Option 1 59 Snap Ring Internal Disperser Shaft Lo...

Page 18: ...2017 CHARLES ROSS SON COMPANY 18 SIDE VIEW CDA 10...

Page 19: ...2017 CHARLES ROSS SON COMPANY 19 VACUUM COVER BEARING HOUSING VIEW CDA 10...

Page 20: ...2017 CHARLES ROSS SON COMPANY 20 HSD BLADE VIEW CDA 10...

Page 21: ...2017 CHARLES ROSS SON COMPANY 21 MIX CAN VIEW CDA 10...

Page 22: ...2017 CHARLES ROSS SON COMPANY 22 THERMOCOUPLE ASSEMBLY LOW PROFILE 1 8 FLUSH MOUNT...

Page 23: ...2017 CHARLES ROSS SON COMPANY 23 APPENDIX VENDOR PRODUCT INFORMATION...

Reviews: