background image

Contact Us 
 

Contact our friendly and professional support representatives for the following: 
 

• 

Name and address of your local dealer 

• 

Product information and pricing 

• 

Technical support 

• 

Upcoming trade show information 

 

General Business Office 
and Technical Support 

613 

 652 

 4886 

After-hours Emergency 

613 

 652 

 4886  ext. 333 

PHONE 

Fax 

613 

 652 

 4425 

General Information 

[email protected] 

E-MAIL 

Technical Support 

[email protected] 

Ross Video Limited 

8 John Street, 
Iroquois, Ontario, Canada 
K0E 1K0 

POSTAL 

SERVICE 

Ross Video Incorporated

P.O. Box 880,  
Ogdensburg, New York, USA 13669-
0880 

 

Visit Us 

 
Please visit us at our website for: 
 

• 

Company information 

• 

Related products and full product lines 

• 

On-line catalog 

• 

Trade show information 

• 

News  

• 

Testimonials 

 
 

 

 

Summary of Contents for 8011A-7DR-004

Page 1: ...Ross Video Limited CMA 8011A 7 Component Monitoring Amplifier User Manual Ross Part Number 8011A 7DR 004 Issue 05...

Page 2: ...opyrighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as a commitment by Ross...

Page 3: ...quipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or as...

Page 4: ...th Canadian ICES 003 Cet appareil numerique de classe A est conforme la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of...

Page 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Page 6: ......

Page 7: ...ualization Setting 2 3 Board Installation 2 3 BNC Labels 2 4 Cable Connections 2 4 LEDs 2 5 SMPTE 269M Fault Reporting 3 1 In This Chapter 3 1 Overview 3 1 Jumper Setup 3 2 Frame Connections 3 2 Detai...

Page 8: ...ii Contents CMA 8011A 7 User Manual Iss 05...

Page 9: ...oss Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new CMA 8011A 7 fits into your overall working environment Equally pleasing is the product...

Page 10: ...11A 7 also outputs six or seven reclocked SDI streams The SDI input has an exceptionally good cable equalizer that will give error free performance with up to 305 meters 1000 ft of Belden 8281 cable S...

Page 11: ...Ross Video 8000 series digital products frames and Leitch 6800 series frames 5 year transferable warranty Documentation Terms The following terms are used throughout this guide Frame refers to the DF...

Page 12: ...1 4 Introduction CMA 8011A 7 User Manual Iss 05...

Page 13: ...wing note ESD Susceptibility Static discharge can cause serious damage to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wear...

Page 14: ...l position 2 CHROMA OFF Used to output luminance only for the best picture on a monochrome monitor NORMAL Blanks all vertical interval information signals 20 line blanking 3 V BLANK SHORT Passes all v...

Page 15: ...the cable length used between the amplifier and analog destination equipment Plug the board into the frame and apply power The equalization control is calibrated for Belden 8281 cable For other types...

Page 16: ...r coax cables to the CMA 8011A 7 when mounted in RossGear 8000 series digital frames 1 IN 3 5 7 2 4 6 8 SDI Input SDI Out 2 SDI Out 4 SDI Out 6 Composite Out 1 SDI Out 1 SDI Out 3 SDI Out 5 SDI out 7...

Page 17: ...e input signal is too low or absent In some circumstances the signal may still be restored correctly but the circuits will be working close to the limit of their capability and reliability cannot be a...

Page 18: ...2 6 Installation and Setup CMA 8011A 7 User Manual Iss 05...

Page 19: ...TE 269M fault reporting The card connects by means of an internal interface circuit to an auxiliary telco connector on RossGear 8000 series frames When the frame connection is interfaced with a custom...

Page 20: ...SMPTE 269M Fault Reporting connection on RossGear 8000 series frames is provided by the auxiliary telco connector AUX A for interfacing with a customer designed alarm system AUX A Connector for SMPTE...

Page 21: ...Specifications In This Chapter This chapter contains the CMA 8011A 7 Technical Specifications table CMA 8011A 7 User Manual Iss 05 Specifications 4 1...

Page 22: ...0 850ps Typical Overshoot 8 SDI Output Delay SDI Input to SDI Output 13ns Number of Outputs 1 or 2 jumper selectable Standards NTSC or PAL composite video Output Impedance 75 Output Return Loss 35dB t...

Page 23: ...wer Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power source a...

Page 24: ...oducts line provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear CMA 8011A 7 are to be conduc...

Page 25: ...DFR 8104A C Digital Products Frame with Cooling Fan Module and Power Supply PS 8102 1RU holds 4 modules includes 1 power supply DFR 8110A Digital Products Frame and Power Supply PS 8102 2RU holds 10 m...

Page 26: ...Notes 6 2 Ordering Information CMA 8011A 7 User Manual Iss 01...

Page 27: ...Notes CMA 8011A 7 User Manual Iss 05 Ordering Information 6 3...

Page 28: ...fter hours Emergency 613 652 4886 ext 333 PHONE Fax 613 652 4425 General Information solutions rossvideo com E MAIL Technical Support techsupport rossvideo com Ross Video Limited 8 John Street Iroquoi...

Reviews: