background image

IMPORTANT NOTE:

 

 Please read carefully and thoroughly all of the 

CAUTIONS, WARNINGS

 

on the inside back cover.

A7.5

www.rosscontrols.com

Online Version
Rev. 11/14/16

0.83

(21.1)

Single Connector Kit 609E94 (not included)

1/2 -14 NPT 

Inlet (Both sides)

1/2 -14 NPT 

Exhaust (Both sides)

4 x 

O

 .34 

Thru for Mounting

1/8 -27 NPT 

x 8 Outlets

7 x 

0.68 (17.3)

0.33

(8.4)

0.68 

(17.3)

4.9

(142.5)

2.03

(51.6)

3.53 ( 89.7)

0.9

(23.9)

1.20

(30.5)

120 (3048)

4.88 (124.0)

6.38

(162.1)

3.12

(79.3)

1.52

(38.6)

1.39

(35.3)

3.75 (95.3)

0.81

(20.6)

3/2 Normally Closed

1

2

3

12

Individual Valve Shut-off (automatic):  

Individual valves can be removed without shutting off 

main air supply to the whole manifold or entire solenoid cabinet.  

• 

Simply remove the valve and an internal check-ball automatically blocks inlet air to that station 

• 

Inlet air is automatically restored to the station when the valve is returned

Construction: 

 Poppet. 

Mounting Type: 

Base.

Solenoids: 

Rated for continuous duty.

Standard Voltages:  

24 volts DC; 110-120 volts AC, 50/60 Hz.  

Power Consumption: 

 

0.03 VA holding on 50/60 Hz; 0.8 watts on DC.

Enclosure Rating: 

 IP65, IEC 60529.

Electrical Connections:

 EN 175301-803 Form C connector.

Ambient Temperature: 

39° to 122°F (4° to 50°F).

Media Temperature: 

 

39° to 175°F (4° to 80°C).

Indicator Light:

  In connector.

Flow Media: 

Filtered air.

Inlet Pressure:  

30 to 150 psig (2 to 10 bar).

4/2 Low-Power Solenoid Pilot Controlled Valves available, consult ROSS.

STANDARD SPECIFICATIONS 

(for valves on this page)

:

3-Way 2-Position Valves - Extended-Duty, 

Single Solenoid Pilot Controlled

Valve/Manifold Assembly

Model Number

C

V

Flying Leads

Central Wiring

8 Station

3900A0713-1

**

3900A1055-1

**

0.5

16 Station

3900A0713-2

**

3900A1055-2

**

0.5

24 Station and over

consult ROSS 

consult ROSS

0.5

**

 Insert voltage code: “

W

” = 24 volts DC; “

Z

” = 110-120 volts AC, 50/60 Hz; 

e.g., 3900A1052-1

W

.  For other voltages, consult ROSS.

3-Way Solenoid Pilot Controlled Pack Valves

Pack Series

Fitting

Fitting Type

Port 

Threads

Model Number

*

Flying Leads

Central Wiring

Metal Swivel

1/8

322E27   

322E27

*

1/4 tube.

Electrical 
Connector

Connector Type

Model Number

Flying Leads

Central Wiring

EN 175301-803 Form C

609E94

consult ROSS

*

 Electrical Connector w/10’ leads.

A

CCessories

 & o

ptions

A7

A

Dimensions –

 inches (mm)

Silencers

Port 
Size

Thread 

Type

Model Number

NPT Threads

BSPT Threads

3/8

Male

5500A3013

D5500A3013

1/2

Male

5500A4003

D5500A3003

Pressure Range:  

0 to 150 psig (0 to 10.3 bar) maximum.

    

Flow Media: 

 Filtered air.

Reviews: