Construction:
Poppet.
Mounting Type:
Base.
Solenoid Pilot:
Rated for continuous duty.
Standard Voltages:
24 volts DC; 110-120 volts AC, 50/60 Hz.
Power Consumption:
8 VA inrush, 6 VA holding on 50 or 60 Hz;
6 watts on DC.
Enclosure Rating:
IP65, IEC 60529.
Electrical Connections:
EN 175301-803 Form A connector.
Ambient Temperature:
5° to 120°F (-15° to 50°C).
Media Temperature:
5° to 175°F (-15° to 80°C).
For temperatures below 40°F (4°C) air must be free of water vapor to
prevent formation of ice.
Flow Media:
Filtered air.
Inlet Pressure:
Vacuum to 150 psig (10 bar).
Manual Override:
Flush; metal, locking and non-locking.
1.3 (32)
2.5
(64)
3.5
(89)
3.1 (79)
Valve is shown with electrical connector
and on a base.
Electrical connector, optional.
3-Way 2-Position Valves, Single Direct Solenoid, Spring Return
Override Type
Valve Model Number
*
C
V
Locking
W1413A1408
**
0.1
Non-Locking
W1413A1409
**
0.1
*
Sub-bases and sub-base manifold ordered separately.
**
Insert voltage code: “
W
” = 24 volts DC; “
Z
” = 110-120 volts AC, 50/60 Hz; e.g., W1413A1408
W
.
For other voltages, consult ROSS.
STANDARD SPECIFICATIONS
(for valves on this page)
:
Sub-Base
Port Threads
Model Number
1/8 NPT
516B91
1/8 BSPP
D516B91
Manifold
Model Number
535K91
Solenoid Pilot Controlled Miniature Valves
W14 Series
1
2
3
12
3/2 Normally Closed
A7
A
CCessories
Electrical
Connectors
Electrical
Connector
Form
Electrical Connector Type
Cord Length
meters (feet)
Cord
Diameter
Electrical Connector Model Number
Without
Light
Lighted Connector
*
24 Volts DC
120 Volts AC
EN 175301-803 Form A Prewired Connector (18 gauge)
2 (6
1/2
)
6-mm
721K77
720K77-W
720K77-Z
EN 175301-803 Form A Prewired Connector (18 gauge)
2 (6
1/2
)
10-mm
371K77
383K77-W
383K77-Z
EN 175301-803 Form A
Connector for threaded conduit
(1/2 inch electrical conduit fittings)
–
–
723K77
724K77-W
724K77-Z
EN 175301-803 Form A Connector Only
–
–
937K87
936K87-W
936K87-Z
*
Lights in connectors with a translucent housing can be used as indicator lights to show when solenoids are energized.
A
Dimensions –
inches (mm)
1
2
2.40 (61)
1.4
(36)
2.5
(64)
1.2
(30)
2
1
A
P
1P
1
P
A
2
T ype
0.63
(16)
0.53
(13.5)
0.94
(24)
0.14
(3.5)
1.25
(32)
0.63
(16)
TOP
1.25 (32)
0.16 (4)
0.35
(9)
0.63
(16)
0.35
(9)
0.63
(16)
Bolt used only to join
Manifold Station
Valve
Manifold