background image

User Manual 

 

RPC-TNC Calibration Kit 

06CK001-150 and 06CK010-150

 

06CK001-150 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : [email protected]

 

Page 

 

6 / 18

 

 

D

ie

se

D

ok

um

e

nt

 is

u

rh

eb

e

rr

ec

h

tli

ch

 g

es

ch

üt

zt

 ●

 T

hi

d

o

cu

m

e

n

t i

p

ro

te

ct

ed

 b

co

py

ri

g

ht

 ●

 R

os

en

b

er

ge

H

o

ch

fr

eq

u

en

zt

ec

h

ni

G

m

bH

 &

 C

o

. K

G

 

1.5 Calibration Certificate 

 

Each calibration kit comes with a calibration certificate. Measurement results and uncertainties for 
all calibration standards, the Gauges and the Torque Wrench are included.  
 
Standard scope of delivery is the Factory Calibration.  
 
Optional  scope  of  delivery  is  the  Accredited  Calibration.  In  this  case  the  electrical  calibration 
standards  of  this  calibration  kit  are  calibrated  instead  in  the  Rosenberger  calibration  laboratory, 
which  is  accredited  by  the  German  accreditation  body  DAkkS  (Deutsche  Akkreditierungsstelle) 
according  to  DIN  EN  ISO  17025.  Calibration  Certificates  issued  by  an  accredited  calibration 
laboratory  are  accepted  worldwide  to  demonstrate  that  measurement  results  are  traceable  to 
national / international standards. 

 

 

Summary of Contents for 06CK001-150

Page 1: ...enztechnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 18 Dieses Dokument ist urheberrechtlich gesch tzt This document is...

Page 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Page 3: ...ibration kit used Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs...

Page 4: ...it Device Part number Remarks Quantity Open circuit plug 06S12L 000S3 1 Open circuit jack 06K12L 000S3 1 Short circuit plug 06S12S 000S3 1 Short circuit jack 06K12S 000S3 1 Calibration load plug 06S15...

Page 5: ...alibration load jack 06K150 C10S3 1 Calibration adaptor plug plug 06S121 S20S3 1 Calibration adaptor jack jack 06K121 K20S3 1 Calibration adaptor plug plug 05S106 S20S3 1 Calibration adaptor jack jack...

Page 6: ...t results and uncertainties for all calibration standards the Gauges and the Torque Wrench are included Standard scope of delivery is the Factory Calibration Optional scope of delivery is the Accredit...

Page 7: ...s are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to mat...

Page 8: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously l...

Page 9: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dy...

Page 10: ...available In cases when the two VNA test ports have different connector systems installed e g RPC TNC and RPC 3 50 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Page 11: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Page 12: ...od connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Page 13: ...the utmost importance that connectors do not damage the test equipment interfaces to which they are connected Poor performance of many coaxial devices and cable assemblies can often be traced to poor...

Page 14: ...ical limits should be done in different orientations averaging up to 4 single measurements When a gauge block is used to initially adjust the gauge a torque spanner should be used to tighten up the co...

Page 15: ...rger com Tel 49 8684 18 0 Email info rosenberger com Page 15 18 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG Figure...

Page 16: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Page 17: ...centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentri...

Page 18: ...n disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting...

Reviews: