10.6. Source Mode
(Available on RMEB 0700-107 when the Operation Mode is set to Standard) This submenu
enables you to set the Source Select mode to a specific state: either Momentary switch mode, or
Constant switch mode.
Highlight
Technician
Source Mode
and press
ENTER
.
Use the ▲▼ buttons to set the option and then press
ENTER
.
Note:
To ensure proper operation, perform a power cycle after changing a setting.
10.6.1. Momentary Mode
Momentary enables you to specify those sources that will be available to On or Off. This
mode also contains an option to specify an Auto Detect source.
If the source specified in the Auto-Detect option is connected, the display will ignore all
source commands. When that source is removed, the monitor will return to normal
momentary operation allowing access to those sources that are set to On.
Note:
When auto-detecting a source, sources 1 & 2 are no longer selectable during
normal momentary operation.
Highlight
Technician
Source Mode
and press
ENTER
. Momentary is the default
setting for the Source Select option. If Source Select is set to Constant, highlight
Source
Select
and press
ENTER.
Use the ▲▼ buttons to switch to
Momentary
, and then press
ENTER
.
Use the ▼ to select
Auto Detect
and press
ENTER
.
Select which video input will be in an auto-detected state and press
ENTER
.
Use the arrow buttons to turn the other video inputs On/Off and press
ENTER
.
Select
Back
and press
ENTER
to return to the Technician Menu.
Press
EXIT
to exit the OSD.
Figure 27 Momentary Switch Mode settings