Reference Manual
00809-0100-4148, Rev BA
July 2010
Rosemount 148
2-2
Figure 2-1. Installation Flowchart
MOUNTING
Mount the transmitter at a high point in the conduit run to prevent moisture
from draining into the transmitter housing.
The Rosemount 148 installs:
• In a connection head or universal head mounted directly on a sensor
assembly
• Apart from a sensor assembly using a universal head
• To a DIN rail using an optional mounting clip
Mounting a Rosemount 148 to a DIN Rail
To attach a head mount transmitter to a DIN rail, assemble the appropriate rail
mounting kit (Part Number 00248-1601-0001) to the transmitter as shown in
Figure 2-2.
START
HERE
Bench
Configuration
?
BASIC SETUP
Set Sensor Type
Set Number of Wires
Set Units
Set Range Values
Set Damping
VERIFY
Simulate Sensor
Input (Optional)
Within
Specifications
?
Refer to Section 4: Operation
and Maintenance
FIELD INSTALL
Mount Transmitter
Wire
Power
Transmitter
FINISHED