3. Operation

31/3/2022

Written and illustrated by Ben Sprules 

Rosemor International Ltd 2022 ©

10

3.1 Before Starting 

All local safety regulations and instructions 
must be observed before each start-up.  The 
escalator/travelator must be inspected jointly 
with the party responsible for the machinery, 
who should also be informed of any 
discoloration or paint stains etc. caused by 
repair and renewal work.

3.2 Check operation of Travelator/Escalator

During the cleaning operation, the 
travelator/escalator will need to move towards 
the machine. Now is a good time to check that 
the travelator/escalator moves as required.

3.2.1 Preparing the Rotomatic (or older ET15B)

For use with the T20:

Note: Check that the Rotomatic has sufficient detergent in the 

detergent tank. Check the operation of the vacuum system and empty 

the waste tank before proceeding with the cleaning. 

It is advised to test the operation of the T20 connected 

to your Rotomatic/ET15B before moving into position 

to clean.

Connect the red T20 plug to the red T10/T20 outlet 

on the rear of your escalator cleaning machine.

Connect the Vacuum Hose to the T20 and the Black 

outlet of the Rotomatic Waste Tank (or the outward 

facing outlet of the ET15B waste tank).

Connect the small detergent tube from the T20 to 

the Q/R fitting on the Rotomatic.

Put the Rotomatic/ET15B into ‘Travelator’ Mode and 

with the T20 stood carefully on its side, press 

‘Auto-Start’ on the Rotomatic/ET15B.

Check that detergent is spraying from the 

‘detergent spray area (11 on pg.9) and that both 

brushes are rotating towards the centre of the 

machine.

The travelator/escalator must 

move towards the T20 during 

cleaning. If the 

travelator/escalator moves 

away, The machine will not 

clean or dry the treads 

properly.

Always keep hands and 

body parts away from the  

rotating brushes. Always  

remove hand/wrist jewelry 

and wear short sleeved shirt 

when inspecting brushes.

Summary of Contents for T20

Page 1: ...nual T20 Attachment Travelator Escalator Deep Cleaning Addon Rosemor International Ltd 1 Bullingdon Ave Wallingford Oxon OX10 7PL TEL 44 01491 838 011 WEB www rosemor com Email info rosemor com Designed Assembled in Oxfordshire UK ...

Page 2: ...lator cleaning machine please see the T20i from Rosemor International The T20 is used while the escalator or travelator is moving towards you which makes it a very quick method to perform a cleaning operation Compared with its predecessor the T10 the T20 has had some important improvements implemented on it Redesigned the detergent dispensing system to provide better detergent coverage and reduce ...

Page 3: ...lls in both handling and operating the machine and of its maintenance and care It is therefore vital that the operator receives instruction and training from either Rosemor International Ltd or one of its specialists before the cleaning machine is used for the first time This operation and maintenance manual only represent additional assistance for the operator in correct and safe use of the clean...

Page 4: ...al safety instructions 6 1 8 Safety Instructions 6 1 9 Information on Warning Signs 6 1 10 Warning Signs Stickers 7 1 11 Product Liability 7 1 12 Emissions 7 2 Technical Data 8 2 1 Location of Components 8 2 2 1 List of Components 9 3 Operation 10 3 1 Before Starting 10 3 2 1 Preparing the Rotomatic 10 3 3 Attach T20 11 3 4 Lynch Pin 12 3 5 Connections 13 3 6 Cleaning Operation 14 3 7 Moving the T...

Page 5: ...ot be liable for any damage resulting from such work all risk in this case will be borne exclusively by the operator Correct use of the machine also includes compliance with the conditions of operation and maintenance stipulated by the manufacturer The automatic escalator deep cleaning machine Rotomatic and T20 are not intended nor suitable for cleaning hazardous dirt or substances The machine is ...

Page 6: ...event slip and trip hazards by cordoning off the working area and placing out adequate signage to inform any person that should enter the area of the hazards that are present such as trailing cables and slippery surfaces 1 8 Safety instructions for mains operated machines Care must be taken that the mains cable incurs no damage by being crushed torn frayed driven over etc This connection must be e...

Page 7: ...mited to Eye protection Hand protection Foot protection Ear protection The operator is expressly notified that the machine must be used only for the intended purpose If the machine is not used for the intended purpose such use will be at the sole risk and responsibility of the user Rosemor International Ltd will not accept any liability in such cases 1 12 Emissions The A assessed equivalent contin...

Page 8: ...2 Description 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 8 2 1 Location of Components 1 2 3 4 5 6 7 8 ...

Page 9: ...in 3 Vacuum Outlet Connects to Rotomatic ET15B waste tank 4 Quick Release Pull Pin 5 Front Transport Wheel 6 Detergent Pipe Inlet Connects to Small Q R fitting on rear of Rotomatic ET15B 7 Motor Drive Connector Connects to T10 T20 Socket on rear of Rotomatic ET15B 8 Rear Transport Wheel 9 Guide Wheel Height Adjuster 10 Guide Wheel 11 Detergent Spray Area 12 Roller Brush 13 Vacuum Channel ...

Page 10: ...g with the cleaning It is advised to test the operation of the T20 connected to your Rotomatic ET15B before moving into position to clean Connect the red T20 plug to the red T10 T20 outlet on the rear of your escalator cleaning machine Connect the Vacuum Hose to the T20 and the Black outlet of the Rotomatic Waste Tank or the outward facing outlet of the ET15B waste tank Connect the small detergent...

Page 11: ...escalator travelator switched off Roll the T20 into position on the travelator escalator so that the T20 is sat just in front of the tread combs Pull the pull pin out and raise up the transit wheels to allow the T20 brushes to engage the treads Allow the pull pin to locate in the upper hole of the cam Next attach the U Bar to the T20 as shown here Note If cleaning an escalator always clean from th...

Page 12: ...es Rosemor International Ltd 2022 12 3 4 Lynch Pin Next wheel the Rotomatic into position Now attach the U Bar to the corresponding brackets on the Rotomatic Transportation Trolley Note For ET15B separate brackets are available to attach to your older trolley ...

Page 13: ...e tank Connect the small detergent tube from the T20 to the small Q R fitting on the Rotomatic Put the Rotomatic ET15B into Travelator Mode After these steps your setup should like this 3 Operation 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 13 Note cables and pipes have been removed for clarity Press Cleaning Mode on the Rotomatic touch screen until Travelator ...

Page 14: ...ated by Ben Sprules Rosemor International Ltd 2022 14 When cleaning an escalator ensure there is enough flat step space for the T20 that none of the step risers can collide with the T20 3 7 Moving the T20 over Once you are satisfied with the cleaning results of the current strip you can move the T20 over to clean the next strip To do this Stop the Escalator Travelator Remove the 2x 12mm pins from ...

Page 15: ...0 on its side unplugged as shown on pg 10 Using a scraper or similar tool remove any built up dirt and grime that may be obstructing the vacuum channel Remove any excess dirt from the brushes and white roller wheels and check everything rotates freely 3 Operation 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 15 The T20 will likely drip dirty water from the undersi...

Page 16: ... Vacuum Channel Blocked A Travelator moves away from T20 A Brushes rotate in the wrong direction towards the outside of the T20 they must rotate towards the centre vacuum channel A Transit wheels have not been lifted T20 does not sit flat on the travelator see pg 9 A Vacuum hose not connected properly Q Streaks or stripes on steps after cleaning A One or more jet nozzle is blocked or obstructed A ...