Fig. 16 Trapped Brush Bristle
3.11.2 Cleaning a Step
Once the Rotomatic is lowered on the step
and you are sure you have the correct
cleaning program selected, the ‘
AutoStart
’
button should be flashing green.
Press the ‘
AutoStart
’ button to commence
the cleaning program.
Depending on the program you have chosen
the machine will run through a cleaning
cycle for up to 1 minute, before coming to a
stop automatically.
When the cleaning cycle is complete, place
one hand on the handle and with the other
hand press and hold the ‘
machine up
’ button
to raise the machine. Fig. 17
Next, gently roll the machine forwards until the
wheels contact and stop against the next step.
Fig. 18
Press and hold the ‘
machine down
’ button and
keep it held until the legs fully retract inside the
machine.
At this point the machine is merely perched on
the edge of the steps. DO NOT LET GO of the
handle at this point! Take the handle with both
hands and push the machine firmly forwards
until it locates fully onto the step. Fig. 19
3. Operation
22/11/2019
Written and illustrated by Ben Sprules
Rosemor International Ltd 2019 ©
21
Automatic Escalator Deep Cleaning Machine – Rotomatic v1.0
Fig. 18
Fig. 19
If the AutoStart button does
not flash, try pressing and
holding the machine down
button, to fully retract the
legs inside the machine.
Fig. 17
Full concentration on the task
at hand is required when
moving the machine up the
escalator. Even a brief lapse in
focus could lead to the machine
falling from the steps. Do not
allow yourself to be distracted
when operating this machine!