2.3.1 List of Touch Buttons, Features and Functions

1. Cleaning Mode Selection: Escalator (or Travelator if using optional T10 attachment).
2. Alarm Menu – Pressing this will take you to a list of any active alarms or alerts.
3. Brush Jog Button – Press and hold to rotate brushes slowly.
4. Vacuum Test Button – Press once to switch on vacuum. Press again to switch it off.
5. Cleaning Program Selector (decrease).
6. Date and Time (used to monitor service intervals and operational logging).
7. Machine Hours/Mins Counter – Records the total amount of time spent cleaning.
8. Seconds remaining of currently selected cleaning program
9. Service & Maintenance Menu – Access to Service & Maintenance features of the machine. 
10. Fluid Test Button – Press and Hold to independently operate cleaning fluid pump. 
11. Cleaning Program Selection  - Displays the currently selected cleaning program (1 – 4).
12. Cleaning Program Selector (increase).
13. Help Menu – Takes you to a range of onboard instructional documentation and diagrams.

There are a choice of 5 automatic cleaning programs to choose from:

Program 1 – 10 seconds 

‘Rapid’ 

automatic cycle

Program 2 – 15 seconds 

‘Fast’ 

automatic cycle

Program 3 – 30 seconds 

‘Standard’ 

automatic cycle

Program 4 – 45 seconds 

‘Deep’ 

automatic cycle

Program 5 – 60 seconds 

‘Intensive’ 

automatic cycle

Each program automatically operates the vacuum, brushes and 
detergent injection for optimal cleaning performance.

Summary of Contents for Rotomatic

Page 1: ... Manual Automatic escalator Deep Cleaning Machine Rosemor International Ltd UNIT F Moses Winter Way Wallingford Oxon OX10 9FE TEL 44 01491 838 011 WEB www rosemor com Email info rosemor com Designed Assembled in Oxfordshire UK ...

Page 2: ...machines use suction to remove the wastewater from the steps This works well but still left some residual moisture and foam in the escalator step treads The new Rotomatic utilizes the very same suction as before with the addition of a powerful air blower nozzle that blasts warm air at the steps leaving them even dryer and ready for use than ever before seen Industrial Touchscreen Controller Rotoma...

Page 3: ...e operator in correct and safe use of the cleaning machine Reading this manual does not qualify any person for safe use of the Rotomatic Rosemor International Ltd or one of its customer service centre s should be informed immediately if any technical fault in this cleaning machine is suspected or has occurred Automatic Self Cleaning Mode Rotomatic is equipped with a revolutionary new feature Self ...

Page 4: ...3 Filling Detergent Tank 15 3 3 1 Replacing Tank 15 3 4 Preparations on site 16 3 5 Safety measures on site 16 3 6 Preliminary inspection and work 16 3 7 Removing machine from trolley 16 3 8 Positioning machine on Escalator 17 3 9 Leg Setting Step Height Adjustment 17 3 10 Select Cleaning Program 18 3 10 1 Cleaning Programs Explained 19 3 11 Cleaning the Escalator 20 3 11 1 Shimmying the machine s...

Page 5: ...manufacturer will not be liable for any damage resulting from such work all risk in this case will be borne exclusively by the operator Correct use of the machine also includes compliance with the conditions of operation and maintenance stipulated by the manufacturer The automatic escalator deep cleaning machine Rotomatic is not intended nor suitable for cleaning hazardous dirt or substances The m...

Page 6: ...ransportation trolley When cleaning an escalator always attempt to prevent slip and trip hazards by cordoning off the working area and placing out adequate signage to inform any person that should enter the area of the hazards that are present such as trailing cables and slippery surfaces 1 8 Safety instructions for mains operated machines Care must be taken that the mains cable incurs no damage b...

Page 7: ...such use will be at the sole risk and responsibility of the user Rosemor International Ltd will not accept any liability in such cases 1 12 Emissions The A assessed equivalent continuous sound level of this machine measures 85 2 dB A It is recommended that the operator wear ear defenders when using this machine 1 13 Leaving the machine unattended If the operator wishes to leave the machine unatten...

Page 8: ...0v 115v available on request Rated power input 1900 W Power output Brush motor inverter controlled 750 W Suction motor supply voltage 1500W Leg Motors inverter controlled 2 x 180 W Pump Solenoid 24vdc 13 W 14W 27W Number of brushes 16 Max Capacity of fresh water tank Max 20L of premixed detergent RC91 20 L Max Capacity of dirty water tank Recommend using 10 15L water and 1L detergent to make lifti...

Page 9: ...9 Written and illustrated by Ben Sprules Rosemor International Ltd 2019 9 Automatic Escalator Deep Cleaning Machine Rotomatic v1 0 2 2 Location of Components 1 2 3 4 5 6 7 8 9 27 29 10 11 12 13 14 15 16 17 28 18 19 Right Left ...

Page 10: ...ription 22 11 2019 Written and illustrated by Ben Sprules Rosemor International Ltd 2019 10 Automatic Escalator Deep Cleaning Machine Rotomatic v1 0 2 2 Location of Components 20 21 22 23 24 25 26 Rear Front ...

Page 11: ...se Cuff Note Never connect grey cuff to black connector or vice versa 13 Black Hose Cuff Note Never connect black cuff to grey connector or vice versa 14 Wastewater Tank Right 15 Lower Machine Button Machine Down 16 Stop Cycle Button 17 Emergency Stop Button 18 Mains Supply Cable 19 Optional T10 Travelator Power Supply Outlet 20 Upper Tank Stop and Retainer NOTE Do not use as a lifting handle 21 G...

Page 12: ...ion 22 11 2019 Written and illustrated by Ben Sprules Rosemor International Ltd 2019 12 Automatic Escalator Deep Cleaning Machine Rotomatic v1 0 2 3 Touch Screen Functions and Layout 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 13: ... total amount of time spent cleaning 8 Seconds remaining of currently selected cleaning program 9 Service Maintenance Menu Access to Service Maintenance features of the machine 10 Fluid Test Button Press and Hold to independently operate cleaning fluid pump 11 Cleaning Program Selection Displays the currently selected cleaning program 1 4 12 Cleaning Program Selector increase 13 Help Menu Takes yo...

Page 14: ...rom accidently being activated when changing brushes Remove blue plastic brush cover 3 Press and hold Brush button Pg 12 on touch screen briefly until a brush aligns with the opening in the chassis Replace brush with same type as removed Repeat this step until all brushes are replaced Replace blue plastic brush access cover 3 Note it is advisable to use a small amount of sealant around the cover a...

Page 15: ...eath Rotomatic Be sure to mop soak up any detergent left on the floor to prevent the chance of someone slipping Note Filling the detergent tank with just 11 16 litres of detergent is recommended as this makes it much easier to lift and maneuver the tanks when full and reduces the chance of a lifting associated injury accident or detergent spillage Every time the detergent tank Pg 9 1 is refilled i...

Page 16: ...ion and Work Inspect the escalator thoroughly and report or take note of any pre existing damage mark or any other form of permanent stain etc Note Rotomatic cannot repair any scratching or erosion caused by historic wear corrosion poor maintenance or accidental damage It may actually appear worse after cleaning as any dirt that might have been disguising it will have been cleaned off and removed ...

Page 17: ...his step is to make important adjustments to the white Pg 10 25 and black feet Pg 9 11 so that they 1 Allow the machine to sit perfectly level on its green gliders when it s lowered into position on an escalator step ready to start cleaning 2 Properly and safely support the machine when it is transitioning from one step up to the next escalator step Only commence leg setting if machine is sitting ...

Page 18: ... lock it in position Check one final time to ensure you have completed the leg setting correctly Raise and fully lower the machine in position once more Check that both green gliders both black rubber feet and both white feet are all sat equally and uniformly on the step Fig 9 below The rear wheels should be approx 1 4mm above the step also If any of the above is not the case you must carry out th...

Page 19: ...e to the operator Program 1 10 seconds Rapid Cleaning For use when there is minimal dirt on the steps or to top up an existing program where a little extra cleaning is required to obtain optimal results Program 2 15 seconds Fast Cleaning This is the standard program cycle for fast efficient cleaning of most escalators that have been regularly cleaned Program 3 30 seconds Standard Cleaning Use this...

Page 20: ...e front end of the machine in the desired direction you wish to move it Fig 13 3 Operation 22 11 2019 Written and illustrated by Ben Sprules Rosemor International Ltd 2019 20 Automatic Escalator Deep Cleaning Machine Rotomatic v1 0 3 Once you have achieved some diagonal movement on the step Lift the handle and pivot the rear end of the machine in the same direction Fig 14 Repeat steps 2 and 3 unti...

Page 21: ...ss and hold the machine down button and keep it held until the legs fully retract inside the machine At this point the machine is merely perched on the edge of the steps DO NOT LET GO of the handle at this point Take the handle with both hands and push the machine firmly forwards until it locates fully onto the step Fig 19 3 Operation 22 11 2019 Written and illustrated by Ben Sprules Rosemor Inter...

Page 22: ...tewater tank by pulling out the grey and black hose cuffs Pg 9 12 13 from the tank lid and set the hoses off to the side Fig 21 Again checking that there are no trapped bristles under the machine Fig 16 you are in position to clean and can proceed to press AutoStart button again to begin cleaning the next step Fig 20 3 11 3 Cleaning an entire Escalator Repeating the above steps will allow you to c...

Page 23: ...handle so that you can get a sturdy handhold at the front and rear of the tank to allowing you to safely lift it our of the machine for emptying Slide the tank back into the machine in the same way you pulled it out Reconnect the vacuum hoses Pay special attention to the colour of the hose cuffs There is one grey cuff and one black hose cuff The grey hose cuff goes to the grey pipe on the lid and ...

Page 24: ...its transportation trolley To place the machine back into it s trolley 1 Raise machine fully using machine up button Fig 25 2 Roll trolley into position around the Rotomatic Fig 26 3 Slide trolley axle through trolley under the Rotomatic Fig 27 4 Press machine down button until legs fully retracted inside of machine and machine is fully supported by the trolley and axle Place security back into en...

Page 25: ...gain access to the underside of the machine this is referred to as Service Mode To put the Rotomatic into service mode first remove both the blue plastic tanks Next remove the machine from the trolley and place it back into the trolley with the front of the Rotomatic entering first as shown below From here set the brakes on the trolley and replace the trolley axle press the machine down button to ...

Page 26: ...Clean Selector Valve Dirty water will pour out from the underside of the Rotomatic during the self clean cycle Make sure you are in an area where this is acceptable 5 Press the Wrench icon on the touchscreen to be taken to the maintenance menu of the machine 6 Now press either the Self Clean button the touch screen or press the AutoStart button to commence the Self Cleaning Mode 7 The Self Clean c...

Page 27: ...if worn Lubricate the round stainless steel static legs connected to the white and black feet to allow proper sliding action through the leg setting clamps Fig 32 Check the black sealing strip is present and correct 4 5 Maintenance after 100 hours cleaning Maintenance work in this case should be carried out as per 30 hours of cleaning Check brush chain sprocket bearings for wear or corrosion Manua...

Page 28: ...r they are found to be worn There are six 6 in total inside your Rotomatic Three 3 of the yellow jets are used for normal escalator cleaning operation and the other 3 are located inside the machine for self cleaning mode and can be serviced and inspected by trained personnel only 50 51 52 53 54 4 Maintenance 22 11 2019 Written and illustrated by Ben Sprules Rosemor International Ltd 2019 28 Automa...

Page 29: ...f information or back to the main help menu 5 2 Alarm Menu If a fault occurs with your Rotomatic an alarm might display on the touchscreen An alarm can also be displayed when a system message needs to be displayed to the operator such as a service reminder You will see a red icon appear in the top left corner of the touchscreen when an alarm is generated Pressing on the Alarm button will take you ...

Page 30: ... full of dirt and debris A Sealing Strip worn or damaged A Static brush heavily soiled or damaged A Vacuum hose connection is loose Q Streaks or stripes on escalator steps after cleaning A One or more Yellow jet is blocked or clogged A Detergent Filter is Blocked A Brushes worn out A Wastewater tank overfull and residue being ejected from exhaust step dryer Q Loud noise coming from machine when cl...